3.2.3 Calibration Menu
See
Figure 3-8. Calibration Menu
UNITS
LB
KG
OZ
G
LB/OZ
Specifies primary units for displayed and printed weight. Values are: LB=pound; KG=kilogram; OZ=ounce;
G=gram; LB/OZ=pounds and ounces.
Alternate Units (ALTUNT Parameter)
LB
KG
OZ
G
LB/OZ
ON
OFF
Alternate units. Determines which units are displayed when the UNITS button is pressed. The value for the
primary unit (selected on the PRIMAR parameter) is always ON.
NOTE:
The LB/OZ setting is not a Legal-for-Trade setting.
CALIBR Menu
Parameter
Choices
Description
Level 2 submenus
WZERO
—
Display and edit the zero calibration A/D count value.
WVAL
—
Display and edit the test weight value.
WSPAN
—
Display and edit the span calibration A/D count value.
REZERO
—
Press ENTER to remove an offset value from the zero and span calibrations.
Use this parameter only after WZERO and WSPAN have been set. See
-
tion about using this parameter.
Table 3-4. Calibration Menu Parameters
FORMAT Menu
Parameter
Choices
Description
Table 3-3. Format Menu Parameters (Continued)
WZERO
*CAL*
Display and edit
zero calibration
A/D count value
Display and edit
test weight value
WVAL
*CAL*
Display and edit
span calibration
A/D count value
WSPAN
*
CAL*
Press Enter to
remove offset from
zero and span
calibrations
REZERO
XXXXXXX
XXXXXXX
VERS
DEFLT
DIG IN
SERIAL
CALIBR
CONFIG
FORMAT