Configuration
©
Rice Lake Weighing Systems
●
All Rights Reserved
15
3.2.2 Format Menu
Figure 3-7. Format Menu
FORMAT Menu
Parameter
Choices
Description
Level 2 submenus
PRIMAR
UNITS
DECPNT
DSPDIV
Specifies the decimal position, display divisions, and units used for the primary units. See Level 3 submenu
parameter descriptions.
ALTUNT
LB
KG
OZ
G
LB/OZ
Specifies which alternate units can be displayed by pressing the UNITS. See Level 3 submenu parameter
descriptions.
NOTE: The LB/OZ setting is not a Legal-for-Trade setting.
Level 3 submenus
Primary Units (PRIMAR Parameter)
DECPNT
888.888
8888.88
88888.8
888888
888880
8.88888
88.8888
or
88 88.8
888 88
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the primary unit display.
Value should be consistent with local legal requirements.
If LB/OZ is selected as the primary unit, DECPNT selections are 88 88.8 and 888 88.
DSPDIV
1D
2D
5D
Display divisions. Selects the minimum division size for the primary units displayed weight.
Table 3-3. Format Menu Parameters
KG
G
OZ
LB
PRIMAR
ALTUNT
DSPDIV
UNITS
DECPNT
OZ
KG
88888.8
8888.88
1D
5D
2D
LB
88.8888
8.88888
888880
888888
OFF
ON
LB/OZ
G
LB/OZ
XXXXXXX
XXXXXXX
VERS
DEFLT
DIG IN
SERIAL
CALIBR
CONFIG
FORMAT
OFF
ON
OFF
ON
OFF
ON
OFF
ON
888 88
88 88.8
If UNITS=LB/OZ,
DECPNT selections are:
888.888