50
iDimension 300
5. Review the Zone of Interest Area (blue rectangle) and the Work Area (orange rectangle) that was
previously set up.
5.4.5
Calibrate the Cameras
In general, the cameras should not require re-calibration after the initial setup.
Re-calibration may be required if:
•
The height of the scanning head has changed
•
The height of the scale has changed
•
A scale has been added or removed from operation
To review the current camera calibration settings, follow the steps below.
1. Select
Calibration
from the
Admin Tools
menu.
2. Select
Camera Calibration
from the
Calibration
menu.
Figure 5-24. Camera Calibration
3. The Confidence levels on each tab indicate the system’s confidence in finding the calibration box. The
image in each tab should be reviewed to confirm that the system correctly identified the calibration box. To
re-calibrate the cameras, select
Edit
to switch into
Configuration
mode.