![Rice Lake IDIMENSION 200 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/rice-lake/idimension-200/idimension-200_installation-manual_1453986040.webp)
Administrator’s Section
37
Image Quality Screen — Field Values
Table 5-8. Image Quality Field Values
Field Value
Description
Values
Iris
This controls the aperture of the high resolution camera’s lens. The larger the
value, the larger the aperture, the brighter the image. However, a larger aperture
also produces a shallower depth of field. A setting of 136 provides best image
quality.
Default Value: 136
Valid Values: 0-255
Adaptive Exposure
Allows the system to auto-sense the lighting conditions and adjust the exposure
accordingly. Intended for use in environments subject to gradual changes in light
conditions.
Default Value: Off
Valid Values: On/Off
Threshold
A threshold value, expressed as a percentage of change in lighting conditions,
above which the system will re-assess and adjust the exposure.
Default Value: 10
Valid Values: 0-100
Exposure
Exposure time, in milliseconds, for the high resolution camera. The longer the
exposure time, the brighter the image. The value for exposure can be changed
manually. Use the
Preview
button to review results.
Default Value: 100
Valid Values: 1ms-255 ms
Light Sensor (lx)
Environmental illumination as detected by the system’s light sensor.
Default Value: 0
Valid Values: N/A
Light Sensor
Up/Down
Low pass filter controlling how fast/slow the light sensor value will respond with
regards to instantaneous reading.
Default Value: 50
Valid Values: 0-100
Gamma
The gamma function brightens dark areas of an image, which corresponds more
to the perception of the human eye. In light areas of an image, the differences in
brightness are condensed for this.
Default Value: 100
Valid Values: 1-1000
Gain
High resolution camera gain setting.
Default Value: 100
Valid Values: Camera
Dependent
Edge Enhancement Determines whether or not a sharpness filter should be applied to all high resolu-
tion images. This setting should normally remain at the default setting of
On
,
which provides the best results for bar code and OCR definition.
Default Value: On
Valid Values: On/Off
Содержание IDIMENSION 200
Страница 2: ...iDimension 300 Industrial Installation Manual PN 169040...
Страница 3: ......
Страница 15: ...12 iDimension 300 6 Click Done to save the settings...
Страница 35: ...32 iDimension 300 General Settings Figure 5 10 iDimension 300 General Settings Main Menu...
Страница 69: ...66 iDimension 300...
Страница 70: ...Administrator s Section 67...
Страница 71: ......