22
MSI-7300 Dyna-Link 2 Technical Manual
6.0
Communication
The
Dyna-Link 2
can communicate with peripheral devices using RS-232 or 802.15.4 wireless. Only one
communications type can exist at a time. The RS-232 port located on the bottom side of the
Dyna-Link 2
can be
used for setup and calibration using a computer and the ScaleCore Connect Software (available Online).
Table 6-1. Communication Menu
Setup Strings – enter a print string number
Print Control – select from paramters:
– disables printing
– press the assigned F-Key and one transmission of the selected string type is
output
– when the tension on the link is stable, one transmission will output. The tension
must return to zero to enable another print to output.
– program the interval in seconds up to 65535 seconds
Output Rate Network ID – print string output rate, enter a number between 0-65635 seconds.
Setting the interval to 0 will set an interval as fast as the system can go.
Enable RF – affects continuous mode only, select On or Off
Scalecore ID – range 1-254 (20-30)
RF Channel – range 12-23
Network ID – range 0 to 99999
RF Network – number of entry screens
1. To enter the communication menu on the
Dyna-Link 2
press
and
simultaneously
2. Press
to scroll through the parameters or settings.
3. Press
to enter a parameter or save a selection and return to previous menu.
4. Press
to save a selection and return to previous menu.
5. Press
to cancel and return to weigh mode.
6. Press to
save.
displays briefly and the
Dyna-Link 2
returns to the weigh mode.
Parameter
Parameter
Description
Print setup. See Section 6.3 on page 24.
1 = Current Wt (Wt-Unit-Mode
)
2 = Net Wt (Wt-Unit-Net
)
3 = Gross Wt (Wt-Unit-Grs
)
4 = Tare Wt (Wt-Unit-Tare
)
5 = Total Wt (Wt-Unit-Total
)
6 = Total Count (#Samples-TCNT
)
7 = Current Wt (no units or mode
)
8 = Reserved
9 = CR-LF (
)
rF
Radio frequency setup. See Section 6.4 on page 25
F1
F2
F2
F1