MSI-7300 Dyna-Link 2 Technical Manual
4.0 Setup
This section describes parameter settings on the
Dyna-Link 2
.
Use the following keys for navigating through the menus when setting up the
Dyna-Link 2
.
1. Press
and
simultaneously to enter setup menu.
2. Press
to scroll through the parameters or settings.
3. Press
to enter a selected parameter or to save a selection and return to previous menu.
4. Press
to save a selection and return to previous menu or to the weigh mode.
Press
to cancel and return to weigh mode.
4.1 Setup Menu
To enter the set up menu, press
and
F2
at the same time.
Parameter
Settings
Description
Func1
Func2
F1 key – configurable to listed parameters. Default is peak hold. In menu mode, functions as the enter/
select key.
F2 key – Configurable to listed parameters. Default is display and function test. In menu mode, functions
as the scroll key.
The F-Key is disabled.
Test – runs an LCD test. See Section 4.2.2 on page 9.
Total – accumulation of multiple weighments. See Section 4.2.3 on page 10.
View Total – activates the total weight display followed by the number of samples. With the total
displayed, press
ZERO
to clear.
Net/Gross – switches the display between Net and Gross modes. See Section 4.2.4 on page 10.
Tare - zeros out a known weight (rigging, a packing container or pallet). See Section 4.2.5 on page 10.
Peak Hold – automatically updates the display when a higher peak weight reading is established. See
Section 4.2.6 on page 10.
2 Units – toggles the force units between pounds and kilograms. See Section 4.2.7 on page 11.
5 Units – scrolls through all available units: lb, kg, Tons (US Short), Metric Tons and kiloNewtons. See
Section 4.2.7 on page 11.
Hi Res – makes the
MSI-7300
more sensitive to motion and movement resulting in a less stable display.
Print – outputs a configured text string to the RS-232 port. See Section 4.2.9 on page 11.
A-OFF
Auto Off – sets the amount of standstill time before the Dyna-Link 2 automatically turns off. See Section
4.3 on page 11
StPt1-8
Greater Than – triggers when the tension exceeds the set value. See Section 4.4 on page 12
Less Than – triggers when the tension is less than the set value.
Off – disables the setpoint parameter.
Total
Total Accumulation - sets the choice for weight accumulation for a single scale.
Disabled when set to off. See Section 4.5 on page 13.
Total On – a manual choice for accummulation. See Section 4.5 on page 13.
Auto Total – settings for automatic accumulations. See Section 4.5 on page 13.
Filter
Weight Filter – allows the scale to adjust to situations where there may be movement. See Section 4.6
on page 14.
Table 4-1. Setup Menu Parameters