PREPARE THE CEMENTATION OF THE BOX

- Dig the pit fully up to the wall or gate post, keeping to the dimensions indicated in the

drawing  and  remembering  that  the  hinge  centre  should  fall  half  way  along  the  Ø  500
dimension (fig 5).

- Attach a 50 mm PVC tube to the water drain outlet on one side of the box, and a heavy

duty  flexible  insulating  tube  of  Ø  32  mm  max  to  the  power  cable  outlet  (Electrical
connections  are  made  remote  from  the  unit  internally  of  a  sealed  junction  box,  which
can be either let into a wall or surface mounted, but must in any event be installed at a
minimum height above ground sufficient to ensure compliance with safety standards).

- Position the foundation box in the pit so that the topmost surface of the cover is flush

with the finished floor or paving.

MAGIC 105° INSTALLATION

- Anchor the box with cement mortar, taking care that none of the mix finds its way into

the enclosure, and checking that 

the shorter sides are faultlessly parallel with the

gate when in the SHUT position

.

- Couple  the  transmission  lever  to  the  output  shaft  after  you  have  greased  it,  checking

first that the bronze thrust bearing is fitted to the shaft.

The connection between gate and lever can be made as indicated in figs 7 and  8.
NB - When converting an existing gate with a load bearing support at ground level, the

MAGIC unit can be utilized as a replacement support (see installation fig 8).

MAGIC 180° INSTALLATION

The MAGIC 180° is universal and can be fitted to a left or right hand opening gate; the
procedure is the same as for the 105°, with the following exception:
- Anchor the box with cement mortar, taking care that none of the mix finds its way into

the  enclosure,  and  checking  that 

the  shorter  sides  are  faultlessly  square  with  the

gate when in the SHUT position, depending on the required opening arc

.

The connection between gate and lever can be made as indicated in figs 9 and 10.
NB - When converting an existing gate with a load bearing support at ground level, the

MAGIC unit can be utilized as a replacement support (see installation fig 10).

Fig.  5

M

MA

AG

GIIC

C 110055°°

FIG.7 - TRANSMISSION LEVER OFFSET UP TO 45 mm 

FROM THE GATE HINGES

A - DO NOT USE
B

- Weld to the gate with the pivot, as shown in Fig. 7.

FIG.8 - TRANSMISSION LEVER GATE LOAD-BEARING SUPPORT

A

- Use only when the gate weighs excessively on the motor. 

B

- Weld with the pivot inserted half-way into the transmission lever slot, as shown in Fig.

8.  

M

MA

AG

GIIC

C 118800°°

FIG.9 - TRANSMISSION LEVER 

WITH MAXIMUM OPENING ARC OF 155°

A - DO NOT USE
B

- Weld to the gate with pivot as shown in Fig. 9.

FIG.10 - TRANSMISSION LEVER 

WITH MAXIMUM OPENING ARC OF 180°

A

- Use  only  when  the  gate  weighs  on  the  motor. 

N.B.  Do  not  use  with  load-bearing

hinges.

B

- Weld to the gate with pivot as shown in Fig. 10.

Fig. 6

A

B

Содержание MAGIC 105

Страница 1: ...pag 15 Technical Features pag 15 Motor and rack fitting pag 16 17 Limit switch and clutch adjustment pag 18 Emergency release system Maintenance pag 19 Safety and Command Accessories pag 20 Declarati...

Страница 2: ...des enfants Les commandes doivent tre plac es au minimum 1 5 m du sol et hors de rayon d action des pi ces mobiles 7 Avant d ex cuter quelconques op rationd installation r glage entrietien de l instal...

Страница 3: ...non in vista es telecomando C C e D C e D automatico C e D C e D C e D esempio tipico sono le chiusure che non accedono a pubblica via A Pulsante di comando a uomo presente cio ad azione mantenuta com...

Страница 4: ...CEMENTAZIONE DEL MAGIC 180 Il MAGIC 180 viene fornito ambidestro quindi potete applicarlo sulla destra o sulla sinistra del cancello indifferentemente e vale quanto detto per la versione 105 tranne c...

Страница 5: ...Fig 7 M Mo od d 1 18 80 0 Fig 9 Fig 10 Fig 8 CAVI ELETTRICI SCARICO ACQUA SALDARE SALDARE M Mo od d 1 10 05 5 Pag 5 di 32 I T A L I A N O...

Страница 6: ...155 B 155 170 C 170 180 Il fermo viene fornito gi montato sufficiente regolarne la vite e bloccarla con l apposito dado MAGIC SUL LATO SINISTRO DEL CANCELLO visto dall interno dell abitazione il ferm...

Страница 7: ...amente a met altezza Fig 14 SICUREZZE ELETTRICHE Si consiglia l utilizzo delle centraline elettroniche di comando K2 o KS2 per 1 o 2 motori monofasi Per i collegamenti ed i dati tecnici degli accessor...

Страница 8: ...RASMETTITORE SYNCRO cod ACG8028 per pi di 2 coppie di fotocellule fino a 4 COPPIA DI CESTELLI DA INCASSO PER FIT SYNCRO cod ACG8051 K2 cod ABK0020 230V cod ABK0021 120V Pag 8 di 32 I T A L I A N O ANT...

Страница 9: ...1x25 h17cm MAGIC porte le vantail du portail et il est possible d enlever le moteur sans avoir ter le vantail MAGIC est r versible et ne n cessite donc pas de d blocage MAGIC peut actionner ais ment d...

Страница 10: ...t terre l installation est possible en se servant du moteur comme support voir installation Fig 8 CIMENTER LE MAGIC 180 Le MAGIC 180 est fourni en version ambidextre et peut tre install indiff remment...

Страница 11: ...Fig 7 M Mo od d 1 18 80 0 Fig 9 Fig 10 Fig 8 CABLE ELECTRIQUE ECOULEMENT DE L EAU SOUDER SOUDER M Mo od d 1 10 05 5 Pag 11 di 32 F R A N A I S E...

Страница 12: ...rture maximum requis A 120 155 B 155 170 C 170 180 L arr t est livr mont il suffit de r gler la vis et de la bloquer avec l crou MAGIC SUR LE C T GAUCHE DU PORTAIL vue de l int rieur de l habitation l...

Страница 13: ...ou 2 moteurs monophas s Pour ce qui est des raccordements et des donn es techniques des accessoires se r f rer leur manuel ACG5000 Pag 13 di 32 F R A N A I S E INSTRUCTIONS TR S IMPORTANTES EN MATI R...

Страница 14: ...RANSMETTEUR SYNCRO code ACG8028 s il existe plus de deux couples de photocellules jusqu 4 COUPLE DE COFFRETS ENCASTRABLES POUR FIT SYNCRO code ACG8051 K2 cod ABK0020 230V cod ABK0021 120V Pag 14 di 32...

Страница 15: ...d in such a way that the motor can be removed for servicing purposes without taking down the gate The MAGIC drive is reversible and therefore requires no release mechanism The MAGIC will comfortably o...

Страница 16: ...h a load bearing support at ground level the MAGIC unit can be utilized as a replacement support see installation fig 8 MAGIC 180 INSTALLATION The MAGIC 180 is universal and can be fitted to a left or...

Страница 17: ...Fig 7 M Mo od d 1 18 80 0 Fig 9 Fig 10 Fig 8 POWER CABLE WATER DRAIN WELD WELD M Mo od d 1 10 05 5 Pag 17 di 32 E N G L I S H...

Страница 18: ...170 C 170 180 The limiter is supplied already assembled the installer need only adjust the screw and secure the relative lock nut MAGIC INSTALLED ON THE LEFT HAND SIDE OF THE GATE viewed from inside...

Страница 19: ...ntrol board for one or two single phase motors For connections and technical data of accessories refer to the appropriate booklets ACG5000 Pag 19 di 32 E N G L I S H IMPORTANT SAFETY INSTRUCTIONS FOR...

Страница 20: ...ising circuit Add the SYNCRO TRANSMITTER code ACG8028 for more than 2 photocells couples up to 4 COUPLE OF BUILT IN BOXES FOR THE FIT SYNCRO code ACG8051 K2 cod ABK0020 230V cod ABK0021 120V Pag 20 di...

Страница 21: ...17cm f r den problemlosen Unterflureinbau MAGIC tr gt das Fl gelgewicht und der Motor kann f r Wartungsarbeiten entfernt werden ohne den Fl gel zu demontieren MAGIC ist reversierbar und ben tigt daher...

Страница 22: ...ion bei der Installation vom Motor bernommen werden siehe Installation Abb 8 INSTALLATION MAGIC 180 MAGIC 180 kann sowohl auf die rechte als auch auf die linke Torseite montiert werden Abgesehen von n...

Страница 23: ...D E U T S C H Pag 23 di 32 Abb 7 M Mo od d 1 18 80 0 Abb 9 Abb 10 Abb 8 ELEKTROKABEL WASSERABFLUSS SCHWEISSEN SCHWEISSEN M Mo od d 1 10 05 5...

Страница 24: ...C 170 180 Der Anschlag wird bereits werkseits montiert seine Position ist lediglich anhand der Endlagenschraube einzustellen und durch Arretieren der entsprechenden Gegenmutter zu fixieren MAGIC AUF...

Страница 25: ...toren empfohlen F r die Anschl sse und technische Daten der Zubeh rteilen verweisen wir auf die entsprechenden Bedienungshandb cher ACG5000 WICHTIGE SICHERHEITSVORSCHRIFTEN F R DIE INSTALLATION 1 Wenn...

Страница 26: ...ozellenpaare bis 4 den SENDER SYNCRO mit Kennnr ACG8028 hinzuf gen ACG8028 f r mehr als 2 Fotozellenpaare bis 4 Paare PAAR F R EINBAUKASTEN F R FIT SYNCRO Kennnr ACG8051 K2 cod ABK0020 230V cod ABK002...

Страница 27: ...aph 2 of the EC Directive 98 37 Machines and following modifications to which respect we point out the ban on its putting into service before being found compliant with what is provided by the Directi...

Страница 28: ...and must be made available for inspection purposes to authorised bodies Dieser Wartungsregister enth lt die technischen Hinweise sowie die Eintragung der durchgef hrten Installation Reparatur und nde...

Страница 29: ...NOTE...

Страница 30: ...NOTE...

Страница 31: ...MAGIC 105 Pag 31 di 32 I F GB D...

Страница 32: ...to fermo Magic 180 CME9825 Semi carcassina SX CME9826 Corona elicoidale CME9832 Bussola flangiata MAGIC CME9836 Piastra fissaggio MAGIC 180 CME9862 Perno per Palmola CMO1310 Rotore con albero CTC1008...

Отзывы: