![RIB AA50110 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/rib/aa50110/aa50110_manual_1453068029.webp)
29
G
B
J5
J4
J2
J3
J6
J7
J8
J17
J16
J14
J12
J13
J11
J15
J18
J10
J9
F1
F
N
J1
J1
N F
Power supply 230 Vac 50/60 Hz - external to the control
panel - (120 V 60 Hz upon request)
J2
SECONDARY
TRANSFORMER
Connectors for secondary 18 Vac transformer
J3
BATTERY
CHARGER (24 V
DC SOLAR
Connector for 24V battery charger board (code ACG4774
optional)
J4
MOTOR
Connector for 24 Vdc motor and 5 Vdc encoder
J5
Connector for flasher 24Vdc (cod. ACG7061)
Pay attention to the polarity.
J6
A+ COM
+ 24Vdc accessories power supply
A-
- 24Vdc accessories power supply
A+TEST
+ 24Vdc photocells self-test power supply
J7
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Barrier opened warning light, operating signal with battery and
low battery (24Vdc 3W max)
COM A+
Contacts common / Positive 24 Vdc
J8
PHOTO 1
Photocells contact 1 (NC)
PHOTO 2
Photocells contact 2 (NC)
STOP
STOP impulse contact (NC)
TLC
Magnetic sensor contact for traffic light control in PARK mode
COM A+
Common contacts / Positive 24 Vdc
J9
SECURITY LOCK
Connector for manual release switch
(factory connected - DO NOT REMOVE!)
J10
OPEN 1
Opening impulse contact (NO) - to enter
OPEN 2
Opening impulse contact (NO) - to exit
CLOSE
Closing impulse contact (NO)
START
Single pulse contact (NO)
B.I.O.
Contact (NO) dedicated to a timer
OK CLOSE
Contact for closing confirmation in PARK mode
COM A+
Common contacts / Positive 24 Vdc
J11
RS485 termination of J12
J12
APP+
Connector for APP+ card
J13
APP
Connector for APP card
J14
SERIAL COM /
SYNC
Connector for serial connection
J15
RADIO
Connector for radio receiver RIB, 24 Vdc supply
J16
RADIO
Connector for radio module ACG8069
J17
433 MHz Radio antenna
J18
AUX CARD
Card 1 relay connector (code ACQ9080) for management of
courtesy light.
Card 3 relay connector (code ACQ9081) for management of
courtesy light or traffic lights.
RUN
Trimmer for high speed adjustment operations
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL9 LED OFF)
LOW SP.OP.
Electronic regulator for low speed on approach in opening
LOW SP.CL.
Electronic regulator for low speed on approach in closure
PROG
Programming button
F1
T 2 A
Transformer protection fuse (external to the card P1 24V)
F2
F10 A
Fuse for motor protection