46
25. INSTALLING A REMOTE
CONTROL DEVICE
Figure 17. Heater Wiring Block
Automation Controller
Heater 2-Wire Controllers (Heat Only)
1. Install wires from the automation controller for
“Heat” on the terminal strip inside the heater on the
terminals: # 44 (Com) & # 46 (Spa).
2. Press and hold the UP and DOWN buttons for 3 +
seconds to enter the Remote Mode.
3. When in the Remote Mode, the maximum setpoint is
the SPA MAX TEMP (104°F (40°C) Default).
4. Press and hold the UP and DOWN buttons for 3 +
seconds to exit the Remote Mode.
5. The digital board will default to the OFF mode
allowing the user to select the appropriate mode
under local control.
NOTE:
When the automation controller has a HEAT
command the heater is in the SPA mode. When the
automation controller does not have a HEAT command
the heater is in the OFF mode.
3-Wire Controllers
1. Install wires from the automation controller for “Heat”
on the terminal strip inside the unit on the terminals:
# 44 (Com), # 45 (Pool) & # 46 (Spa).
2. Set the Remote Pool to “Heat” or “Auto” in the
INSTALLER menu. Selecting “Heat” will allow
remote heating of the pool. Selecting “Auto” will allow
heating & cooling of the pool around the SETPOINT
value established in the USER mode (HEAT/COOL
models only). The control will use this value as the
Heating setpoint and the Cooling Setpoint will be the
SE COOLING DEADBAND (established in
the INSTALLER menu).
3. Press and hold the UP and DOWN buttons for 3 +
seconds to enter the Remote Mode.
4. When in the Remote Mode, the maximum setpoint
is the SPA MAX TEMP (Spa) & POOL MAX TEMP
(Pool).
5. Press and hold the UP and DOWN buttons for 3 +
seconds to exit the Remote Mode.
6. The digital board will default to the OFF mode
allowing the user to select the appropriate mode
under local control.
2-Wire Controllers For “Chill” Mode
– Heat /Cool Models Only
1. Install wires from the automation controller for the
“CHILL” mode on the terminal strip inside the unit on
the terminals: # 44 (Com) & # 45 (Pool).
2. Set the Remote Pool in the INSTALLER menu to
“Cool”.
3. Set the desired COOL SETPT setpoint temperature
in the POOL mode.
4. Press and hold the UP and DOWN buttons for 3 +
seconds to enter the Remote Mode.
5. When in the Remote Mode, the operating setpoint
is the COOL SETPT value established in the USER
menu.
NOTE:
Heating of the water will automatically occur if
the temperature drops to a value equal to the COOLING
DEADBAND degrees below the cooling setpoint.
6. Press and hold the UP and DOWN buttons for 3 +
seconds to exit the Remote Mode.
7. The digital board will default to the OFF mode
allowing the user to select the appropriate mode
under local control.