69
INSTALLATION INSTRUCTIONS
High-Altitude DIP Switch Adjustments (cont.)
Printed Circuit
Board (PCB)
Dip Switches
3
Dip switch
adjustment
3,280 feet
(1,000 m)
thru
6,560 feet
(2,000 m)
5
2
Removethefrontcoverpanelonthewaterheater.
FindDIPSwitch2locatedinthetop-rightportionof
thePCB.Theswitchlabeled“DIP2”isthebottom
switch.
Thefactorysettingsforthisswitchshouldallbein
theOFFposition(DOWN).
Ifaltitudeisabove3,280ft.(1,000m)andbelow
6,560ft.(2,000m),changethethirdswitchon“DIP
2”totheONposition(UP).
Ifaltitudeisabove6,560ft.(2,000m)andbelow
9,840ft.(3,000m),changethefourthswitchtothe
ONposition(UP).
NOTICE:
DonotalteranyotherDIPswitch
settings.Themanifoldpressurewillbereduced
accordingly.
Replacethefrontcoverpanel.
Turnonthegasandwatertothewaterheaterby
openingtheshut-offvalves.