58
Electrical
INSTALLATION INSTRUCTIONS
Remote Control Selection and
Location
WARNING:
Fieldwiringconnectionsand
electricalgroundingmustcomplywithlocalcodesor,
intheabsenceoflocalcodes,withthelatestedition
oftheNationalElectricalCode,ANSI/NFPA70,orin
Canada,CanadianElectricalCode,CAN/CSAC22.1,
Part1.
NOTICES:
•Theprovidedremotecontrolwillallowmaximum
temperaturesettingsof120°F(49°C).Temperatures
upto140°F(60°C)forresidentialapplicationsandup
to185°F(85°C)forcommercialapplications*canbe
achievedwiththeMAIN(UMC-117)remotecontrol.
Onlyqualifiedservicepersonnelshouldperformthis
adjustment.
•Anoptionalcable(EZLink
Cable
TM
)canbepurchased
separatelytomanifoldtwowater
heaterstogether.
•Donotattempttodisassemble
aremotecontrol.Allcontrols
aresealedandcalibratedfor
accuratewaterheatercontrol
andoperation.
Oneremotecontrolisprovidedwiththewater
heater.Additionalremotecontrolsmaybepurchased
separately.Theavailableremotecontrolsarelistedin
thefollowingchart.Uptothreeremotecontrolscan
beusedwiththewaterheater.Noothermanufacturer’s
controlsaresuitableforusewiththiswaterheater.
Reviewthefollowingconsiderationsbefore
determiningthelocationoftheremotecontrol(s):
•Donotinstallanyremotecontrol
outdoorsorwhereitcancomein
contactwithwater.
•Avoidinstallingtheremotecontrolinthe
followingareasand/orconditions:
–areaexposedtoheat.
–areaexposedtosteam.
–areaexposedtooil.
–areaexposedtodirectsunlight.
–areasnearstoredorused
flammableproducts.
•Placeremotecontroloutofchildren’sreach.
•Theremotecontrolshouldbeinstalledina
convenientlocation(e.g.,kitchen,laundryroom,
utilityroom,ordirectlynexttothewaterheater).
•Themaximumdistancebetweenthewaterheaterand
theremotecontrolinstallationlocationislimitedto
195ft.(59m)ofwire.
RemoteControl
ModelNumber
RemoteControl
Description
Temperature
SetPointRange
Availability
UMC-117
MAIN
100°F–120°F(38°C–49°C)
FactoryDefault
85°F(29°C)
125°F–140°F(52°C–60°C)
QualifiedTechnician
AdjustmentforResidentialProducts
85°F(29°C)
125°F–185°F(52°C–85°C)
QualifiedTechnician
AdjustmentforCommercialProducts*
USC1-117
BATH1
100°F–120°F(38°C–49°C)
Optional(SoldSeparately)
85°F(29°C)
QualifiedTechnicianAdjustment
USC2-117
BATH2
100°F–120°F(38°C–49°C)
Optional(SoldSeparately)
85°F(29°C)
QualifiedTechnicianAdjustment
MIC-6orMIC-185**
ManifoldSystem
ManifoldSystem
Optional(SoldSeparately)
*Acommercialconversionkitcanbepurchasedtoachievetemperaturesupto185°F(85°C).
**Whenamanifoldsystemisinstalled,themainremotecontrolconnectedtothemanifoldcontroller
(MIC-6orMIC-185)haspriorityovertheremotecontrolsconnectedtothewaterheater.
Electrical Wiring