49
INSTALLATION INSTRUCTIONS
Opentheshut-offvalveintheCOLDwaterInletline
tocheckthewaterflowthroughthewaterheater.
Closetheshut-offvalveandremove,clean,and
replacethewaterfilter.
NOTICES:
•BesuretoconnecttheCOLDwaterinletandthe
HOTwateroutletasshownonthewaterheater.If
reversed,thewaterheaterwillnotfunction.
•TheflowrateofHOTwatermayvarywhenmorethan
twofaucets(appliances,fixtures,etc.)arebeing
usedsimultaneously.
•ThepipesMUSTbecompletelydrainable.IftheHOT
waterfaucetsarelocatedatapointhigherthanthe
waterheater,placeadrainvalveatthelowestpoint.
Itisrecommendedtouseunionsandflexiblecopper
connectionsattheCOLDandHOTwaterlines.They
allowthewaterheatertobedisconnectedeasilyfor
servicing.
Usethefollowingguidelineswhenconnecting
theHOTWATEROUTLET:
•Connectionsbetweenthewaterheaterandpoint(s)
ofuseshouldbeasshortaspossible.
•Localcodesshallgovernthepipingusedforwater
connections.
•Toconserveenergyandtopreventfreezing,insulate
bothCOLDandHOTwatersupplylines.Donot
insulatedrainlineorpressure-reliefvalve.
5
4
Pressure
Relief Valve
Pressure
Relief Valve
Cold Water
Service Valve
Cold Water
Service Valve
Water
Inlet
Water
Inlet
Water
Outlet
Water
Outlet
Hot Water
Service Valve
Hot Water
Service Valve
Drain
Drain
Water Piping Arrangement With Service Valve Kit
Servicevalvekitsareavailableonalltanklesswater
heatersystems.Allkitsincludetwofull-portisolation
valvestobeusedintheCOLDandHOTwaterlines.
Wheninstalled,thesevalvesallowonepersonfull
diagnostictestingandeaseofflushingthesystem.
Contactyourdistributororplaceofpurchasefor
availabilityandinstallationinformation.
Water Supply Installation (cont.)
Plumbing