27
TM061 Rheem 27 Water Star Service Instructions
– Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by
Service. Al
l printed copies not bearing this statement in RED are deemed “uncontrolled”
Fault-Finding Tests 5 - 7
Test 5
Test 6
Conduct test with no water flow.
Using a multimeter set on the DC volts scale,
measure the voltage between 3 Red and 2 Black
at terminal S on the control PCB.
Normal voltage should be between DC11
– 17V.
Conduct test with water flowing.
Using a multimeter set on the DC volts scale,
measure the voltage between 1 Brown and 2
Black at terminal S on the control PCB.
Normal voltage should be between DC2
– 5V.
Test 7
Remove the flow sensor turbine. Refer to
„Flow Sensor Turbine‟ procedure on page 53.
Check for excessive wear of turbine or blockage by foreign material such as thread tape. The power
must be isolated during water flow sensor removal.