background image

      

                     Revision 2/2021                                     

 

14190 E. Jewell Avenue, Suite 4, Aurora CO 80012 - TEL: 303-366-1234 – Proudly Made in the USA 

www.rfidinc.com

 

Model 8075E Operations Manual v7.21 

42

 

 

 

Warranty 

RFID, Inc. products are warranted against defects in materials and workmanship for one (1) year from 
date of shipment.  RFID, Inc. shall, at its option, either repair or replace products that prove to be 
defective and are returned with freight prepaid to RFID, Inc.’s plant within the warranty period.  The 
foregoing warranty shall not apply to defects resulting from abuse, misuse, accident, alteration, neglect 
or unauthorized repair or installation. RFID, Inc. shall have the right of final determination as to the 
existence and cause of the defect. 

THE WARRANTY SET FORTH ABOVE IS EXCLUSIVE AND NO OTHER WARRANTY, 
WHETHER WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED.  RFID, Inc. SPECIFICALLY 
DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE.   

The remedies provided herein are Buyer's sole and exclusive remedies.  In no event shall RFID, Inc. be 
liable for direct, indirect, special, incidental or consequential damages, (including loss of profits) whether 
based on contract, tort, or any other legal theory. 

Содержание 8075E

Страница 1: ...ble to product owners and users for integration purposes Proprietary and confidential information is contained herein therefore this document is protected by all applicable international intellectual property laws The information contained in this document is constantly subject to revision see Rev number at top of each page ...

Страница 2: ...eger Data 7 SW1 SW2 Dipswitches 7 RW RO read write or read only 8 Summary Default Settings 8 Serial Port Settings 9 Serial Port Commands to the Interface 10 Serial Port Commands to the Smart Antenna RFID Readers 12 Configuring PROFINET LED Status Lights 13 Setting up PRFINET Interface 14 Issuing Commands via PROFINET 15 I O Command Bits 1 Byte 15 Example Module setups Integer Mode Smart Antenna Re...

Страница 3: ...01 8075 04SA08 Model 8075E 04SA08 PROFINET Interface CAN Smart Antennas M12 connector 24vdc 8 characters 8075E 14SA08 801 8075 14SA08 Model 8075E 14SA08 PROFINET Interface CAN Smart Antennas pigtail wiring 24vdc 8 characters 8075E 24SA08 801 8075 24SA08 Model 8075E 24SA08 PROFINET Interface CAN Smart Antennas dual pigtail wiring 24vdc 8 characters 8075E 04SA16 801 8075 04SA16 Model 8075E 04SA16 PR...

Страница 4: ...be skipped or ignored Dual pigtail wiring would be used if the Interface is to be located in the center of the trunk network line of Smart Antenna RFID Readers thus providing a connection in either direction or an M12 T Connector can be used to split the single on board M12 connector into two directions Specifications Physical Dimensions w o connectors 4 8 square x 2 175 122mm square x 55mm Weight...

Страница 5: ...on 2 2021 14190 E Jewell Avenue Suite 4 Aurora CO 80012 TEL 303 366 1234 Proudly Made in the USA www rfidinc com Model 8075E Operations Manual v7 21 5 Drawing PROFINET Interface w M12 Connectors Drawing Shown ...

Страница 6: ... regulated linear or switching power sources having the characteristics defined in the Specifications section of this document 9 to 28 volts The Interface should be operated from a grounded supply that has the same ground reference as the host computer or logic device Cabling the Reader Power The Interface is delivered with two power connection options an M12 connection or connection to bare pigta...

Страница 7: ... RFID Tags RFID Tags store 8 or 16 ASCII characters limited to capital letters numbers and some symbols Smart Antenna Readers operate at 9VDC to 28VDC consuming 160mA max Integer Data Although the Smart Antenna RFID Readers and Tags use 8 or 16 character formats the Model 8075E Interface can convert DINT data from the PROFINET scanner to 8 16 character numerical strings and convert the string from...

Страница 8: ...l Duplex 9600 8 N 1 Single Read Mode PROFINET CAN RW Integer Dynamic IP Address Single Tag Report Read Mode Defaults are noted with an asterisk in tables below Switch 1 LSB Switch 2 Switch 3 Smart Antenna Data Type OFF ON OFF CAN ASCII RW ON ON OFF CAN INTEGER RW OFF ON ON CAN ASCII RO ON ON ON CAN INTEGER RO OFF OFF OFF SERIAL ASCII RW ON OFF OFF SERIAL INTEGER RW OFF OFF ON SERIAL ASCII RO ON OF...

Страница 9: ...Port Hardware Select The PROFINET Interface can only use even values The extra byte of data must be ignored TYPE CMD DATA Total Actual SERIAL ASCII RW 1 16 17 18 SERIAL INTEGER RW 1 4 5 6 SERIAL ASCII RO 1 16 17 18 SERIAL INTEGER RW 1 4 5 6 Table 5 Serial Port PROFINET Data Sizes Start End Characters for Serial to PROFINET Bridge Mode This section pertains only to use of the Interface when linked ...

Страница 10: ...as a Carriage Return Example 3 1S00 sets the start character to none 2NNOO Change Reader Address Format 2 Set Reader CAN address NN New CAN address OO Current old CAN address Valid Addresses 01 to 32 Response OK FAILED1 or FAILED2 Example 23001 change Reader from address 01 to address 30 Example response 1 OK 01 existed on the CAN bus and has been reset to 30 Example response 2 FAILED1 01 does not...

Страница 11: ...operating mode This command changes the data output mode to SINGLE on the PROFINET connection meaning a Tag will be read and reported one time Format S Single Mode Response OK Example S SC This command changes the data output mode to SINGLE on the Serial connection Format SC Single Mode Response OK Example SC P This command changes the data output mode to POLLING on the PROFINET connection Use TAA...

Страница 12: ...ess V view Response The value of addressed Reader write mode Example V07 Read WRITE MODE value of Reader 07 Example response 07 18 07 reader 18 WRITE MODE TAA This command erases the Readers Tag buffer causing it to read the tag again if one is present If the Reader does not respond within 400mS the master ends the command by sending a lower case e If a Tag is present to the Reader then the master...

Страница 13: ...low are detailed explanations of each LED1 Network Status Off No power or no IP address Green Ethernet IP connection established Green Flashing No Ethernet IP connection established Red Duplicate IP address detected Red Flashing Ethernet IP connection timed out Alternating Red Green Self test in progress LED2 Module Status Off No power Green Ethernet IP connection established Green Flashing No Eth...

Страница 14: ...234 Proudly Made in the USA www rfidinc com Model 8075E Operations Manual v7 21 14 MS Link Activity Off No power Green Connected to Ethernet network Green Flashing RX TX Activity Alternating Red Green Self test in progress Setting up PRFINET Interface You need a GSDML XML file ...

Страница 15: ...one on any setup It is via this byte that commands are sent from the PROFINET scanner to the Smart antennas The In Byte contains error bits to indicate command failure types Data type bits are also represented They indicate if ASCII or Integer mode in in use Command Byte Out from scanner Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write with Zeros Command code bits Out Toggle...

Страница 16: ...it every time it loads new values on to the field bus In Command Byte bit codes WRITE_TAG 0 0 1 SINGLE_MODE 0 1 0 POLLING_MODE 0 1 1 TRANSFER_TAG 1 0 0 WRITE_MODE 1 0 1 VIEW_WRITE_MODE 1 1 0 Table 7 Command Bits 1 3 Successful command 0 0 Bad read or write Ins data not valid 0 1 No Response from read head 1 0 Invalid Command or Command Parameters 1 1 Table 8 ERROR Bits 4 5 Smart Antenna ASCII 0 0 ...

Страница 17: ...Reader Integer Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 0 0 1 Toggle Address Not Used Smart Antenna Address DATA 0 Data to Write 32 Bit Integer DATA 1 DATA 2 DATA 3 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 0 0 1 Toggle Address Not Used Smart Antenna Address DATA 0 Written Data 3...

Страница 18: ... Used Write With Zeros DATA 1 DATA 2 DATA 3 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 0 1 0 Toggle Address Not Used Smart Antenna Address DATA 0 Not Used Unmodified DATA 1 DATA 2 DATA 3 ERROR Bits 00 Successful Command 10 No Response from Read Write Head Polling Mode Command Smart Reader Antenna Integer Mode Scanner Out Byte BIT 7 BIT 6 ...

Страница 19: ...response from Read Write Head Transfer Command for Polling Mode Smart Reader Antenna Integer Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 0 0 Toggle Address Not Used Smart Antenna Address DATA 0 Not Used Write With Zeros DATA 1 DATA 2 DATA 3 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bit...

Страница 20: ... 2 DATA 3 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 1 0 1 Toggle Address Not Used Smart Antenna Address DATA 0 Not Used Unmodified New Write Mode Value DATA 1 Not Used Unmodified DATA 2 DATA 3 ERROR Bits 00 Successful Command New Write Mode Set 01 Failure to Set new Write Mode 10 No Response from Read Write Head View Write Mode Command S...

Страница 21: ... 1 Not Used Unmodified DATA 2 DATA 3 ERROR Bits 00 Successful Command Data Valid 10 No Response from Read Write Head Example Module setups ASCII Mode Smart Antenna Readers Write Tag Command Smart Antenna Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 0 0 1 Toggle Address 2 Bytes Smart Antenna ASCII Address High Smart Antenna ASCII A...

Страница 22: ... ASCII Address Low DATA 00 Data Written 16 Bytes in ASCII DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful Data valid 01 Failure Data not valid 10 No response from Read Write Head Single Mode Command Smart Antenna Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not...

Страница 23: ... DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 0 1 0 Toggle Address 2 Bytes Smart Antenna ASCII Address High Smart Antenna ASCII Address Low DATA 00 Not Used Unmodified DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 1...

Страница 24: ...BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 0 1 1 Toggle Address 2 Bytes Smart Antenna ASCII Address High Smart Antenna ASCII Address Low DATA 00 Not Used Write With Zeros DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 C...

Страница 25: ...ATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful Command 10 No response from Read Write Head Transfer Command for Polling Mode Smart Antenna Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 0 0 Toggle Address 2 Bytes Smart Antenna ASCII Address High Smart Antenna ASCII Address Low DATA 00 Not Used Write With Zeros DAT...

Страница 26: ... 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 1 0 0 Toggle Address 2 Bytes Smart Antenna ASCII Address High Smart Antenna ASCII Address Low DATA 00 Data Read 16 Bytes in ASCII DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful New Data 01 Successful No New Data 10 No Response from Read Write Head Wri...

Страница 27: ...s Smart Antenna ASCII Address Low DATA 00 New Write Mode Value DATA 01 Not Used Write With Zeros DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 1 0 1 Toggle Address Smart Antenna ASCII Address High Address Smart Antenna ASCII Addres...

Страница 28: ...ode Set 01 Failure to Set new Write Mode 10 No Response from Read Write Head View Write Mode Command Smart Antenna Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 1 0 Toggle Address Smart Antenna ASCII Address High Address Smart Antenna ASCII Address Low DATA 00 Not Used Write With Zeros DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA...

Страница 29: ...CII Address Low DATA 00 Current Write Mode Value DATA 01 Not Used Unmodified DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful Command Data Valid 10 No Response from Read Write Head Example Module setups Integer Mode Serial Smart Antenna Reader Write Tag Command Serial Reader Integer Mode Scanner Out Byte BIT 7 ...

Страница 30: ...R Bits 00 Successful Data valid 01 Failure Data not valid 10 No response from Read Write Head Single Mode Command Serial Reader Integer Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 0 1 0 Toggle DATA 0 Not Used Write With Zeros DATA 1 DATA 2 DATA 3 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR...

Страница 31: ...T 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 0 1 1 Toggle DATA 0 Not Used Unmodified DATA 1 DATA 2 DATA 3 ERROR Bits 00 Successful Command 10 No response from Read Write Head Transfer Command for Polling Mode Serial Reader Integer Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 0 0 Toggle DATA 0 Not Used Write Wit...

Страница 32: ... Not Used New Write Mode Value DATA 1 Not Used Write With Zeros DATA 2 DATA 3 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 1 0 1 Toggle DATA 0 Not Used Unmodified New Write Mode Value DATA 1 Not Used Unmodified DATA 2 DATA 3 ERROR Bits 00 Successful Command New Write Mode Set 01 Failure to Set new Write Mode 10 No Response from Read Write H...

Страница 33: ...urrent Write Mode Value DATA 1 Not Used Unmodified DATA 2 DATA 3 ERROR Bits 00 Successful Command Data Valid 10 No Response from Read Write Head Example Module setups ASCII Mode Serial Readers Write Tag Command Serial Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 0 0 1 Toggle DATA 00 Data To Write 16 Bytes in ASCII DATA 01 DATA 02 ...

Страница 34: ...0 1 Toggle DATA 00 Data Written 16 Bytes in ASCII DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful Data valid 01 Failure Data not valid 10 No response from Read Write Head Single Mode Command Serial Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write Wit...

Страница 35: ...ATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 0 1 0 Toggle DATA 00 Not Used Unmodified DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful Command 10 No Response from Read Write H...

Страница 36: ... 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 0 1 1 Toggle DATA 00 Not Used Write With Zeros DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 0 1 1 Toggle DATA 00 Not Used Unmodified DATA 01 DATA 02 DATA 03 DA...

Страница 37: ...se from Read Write Head Transfer Command for Polling Mode Serial Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 0 0 Toggle DATA 00 Not Used Write With Zeros DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 ...

Страница 38: ...ATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful New Data 01 Successful No New Data 10 No Response from Read Write Head Write Mode Command Serial Reader ASCII Mode Scanner Out Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 0 1 Toggle DATA 00 New Write Mode Value DATA 01 Not Used Write With Zeros DATA 02 DATA 03 DA...

Страница 39: ... Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 1 0 1 Toggle DATA 00 New Write Mode Value DATA 01 Not Used Unmodified DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 ERROR Bits 00 Successful Command New Write Mode Set 01 Failure to Set new Write Mode 10 No Response from Read Writ...

Страница 40: ...T 3 BIT 2 BIT 1 BIT 0 CMD Not Used Write With Zeros 1 1 0 Toggle DATA 00 Not Used Write With Zeros DATA 01 DATA 02 DATA 03 DATA 04 DATA 05 DATA 06 DATA 07 DATA 08 DATA 09 DATA 10 DATA 11 DATA 12 DATA 13 DATA 14 DATA 15 Response Scanner In Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CMD Data Type Bits ERROR Bits 1 1 0 Toggle DATA 00 Current Write Mode Value DATA 01 Not Used Unmodified DATA...

Страница 41: ... them an operational address 1 Use the command 2xx01 to assign the new address where xx new address 2 You should receive the response of OK If so skip the rest you are done 3 If you receive a FAILED_X response refer to Serial Port Commands to the Smart Antenna RFID Readers on page 12 for details Reassign Smart Antenna Reader Address 1 If you don t know a Smart Antenna Reader s address disconnect a...

Страница 42: ...ot apply to defects resulting from abuse misuse accident alteration neglect or unauthorized repair or installation RFID Inc shall have the right of final determination as to the existence and cause of the defect THE WARRANTY SET FORTH ABOVE IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IMPLIED RFID Inc SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AN...

Отзывы: