Page 1: ...Leica Zeno GG04 plus User Manual Version 1 0 English ...

Page 2: ...ne are trademarks of Apple Inc registered in the U S and other countries iPad Air iPad pro and iPad mini are trademarks of Apple Inc Refer to the Apple Trademark List at www apple com legal intellectual property trademark appletmlist html for the correct trademark symbol All other trademarks are the property of their respective owners This manual applies to all models of the Leica GG04 plusGNSS in...

Page 3: ...ms service centres Access detailed information on the services performed and download your latest calibration cer tificates and service reports mySupport View the current service status and full service his tory of your products in Leica Geosystems service centres Access detailed information on the services performed and download your latest calibration cer tificates and service reports myTraining...

Page 4: ...9 3 2 1 Operating Principles 19 3 2 2 Battery for GG04 plus 19 3 3 Equipment Setup as a Real Time Rover 20 3 3 1 Setup with Leica Zeno GIS Hardware and Software 20 3 3 2 Setup with Third Party Mobile Devices 21 3 4 Connection with Leica Zeno GIS Software 23 3 5 Correction Service Spot Lite and Spot Prime PPP 26 4 Care and Transport 27 4 1 Transport 27 4 2 Storage 27 4 3 Cleaning and Drying 27 5 Te...

Page 5: ...ying levels of hazards and risks related to personal injury and property damage For your safety it is important to read and fully understand the fol lowing table with the different signal words and their definitions Supplemen tary safety information symbols may be placed within a warning message as well as supplementary text Type Description DANGER Indicates an imminently hazardous situation which...

Page 6: ...s without the prior explicit approval of Leica Geosystems Inadequate safeguards at the working site Controlling of machines moving objects or similar monitoring application without additional control and safety installations 1 3 Limits of Use Suitable for use in an atmosphere appropriate for permanent human habita tion not suitable for use in aggressive or explosive environments DANGER Local safet...

Page 7: ...nsure that the national laws regulations and conditions for the opera tion of the product are respected 1 5 Hazards of Use DANGER Because of the risk of electrocution it is dangerous to use poles levelling staffs and extensions in the vicinity of electrical installations such as power cables or electrical railways Precautions Keep at a safe distance from electrical installations If it is essential...

Page 8: ...thorised specialist To prevent damages due to indirect lightning strikes voltage spikes cables for example for antenna power source or modem should be pro tected with appropriate protection elements like a lightning arrester These installations must be carried out by an authorised specialist If there is a risk of a thunderstorm or if the equipment is to remain unused and unattended for a long peri...

Page 9: ...ewellery keys metallised paper or other metals the battery can overheat and cause injury or fire for example by storing or transporting in pockets Precautions Make sure that the battery terminals do not come into contact with metal lic objects WARNING Incorrect fastening of the external antenna to vehicles or transporters poses the risk of the equipment being broken by mechanical influence vibrati...

Page 10: ...Geosystems distributor WARNING Only Leica Geosystems authorised service centres are entitled to repair these products CAUTION If the accessories used with the product are not properly secured and the product is subjected to mechanical shock for example blows or falling the product may be damaged or people can sustain injury Precautions When setting up the product make sure that the accessories are...

Page 11: ...uctors The diameter of the air terminal should be kept to a minimum to reduce GNSS signal shading 2 On metallic structures Protection is as described for non metallic structures but the air terminals can be connected directly to the conducting structure without the need for down conductors GS_039 a b c a Antenna b Support structure c Air terminal GS_040 e d c a b a Antenna b Lightning conductor ar...

Page 12: ...mputers or other electronic equipment pay attention to the information about electromag netic compatibility provided by the manufacturer CAUTION Disturbances caused by electromagnetic radiation can result in erroneous measurements Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot completely exclude the possibil ity that the p...

Page 13: ...aircraft 1 7 FCC Statement Applicable in U S WARNING This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio fre quency energy and if not installed and u...

Page 14: ...for compliance could void the user s authority to operate the equipment 0015185_001 0015185_001 This device contains a transmitter IC 5325A 0946 FCC ID PVH0946 R 204 210003 Model GG04 Art No 123456 Equip No 1234567 S No 1234567 Power 12V nominal 0 3 A max Leica Geosystems AG CH 9435 Heerbrugg Manufactured 20XX Made in Switzerland 005044_003 005044_003 Labelling GG04 plus Labelling internal bat ter...

Page 15: ...ncy and multi satellite system can be used for high accuracy data collection with real time corrections coming by L band satellites Precise Point Positioning PPP can increase positioning accuracy through various correction services like SBAS RTCM corrections or Spot options Precise Point Positioning PPP The instrument contains several special features Robust instrument with integrated antenna and ...

Page 16: ...luetooth and signal reception LEMO 1 connector Serial by RS232 or USB communication 5 8 Whitworth thread Mounting the instrument for observation 012209_001 c d a b e f g a LEMO 1 connector RS232 and USB port b Whitworth thread for instrument mounting c Tracking LED d Bluetooth LED e Power LED f ON OFF key g Battery compartment Do not open the instrument or remove any connector as this action impai...

Page 17: ...and Leica Zeno hardware or selected Android iOS or Windows devices to collect or verify assets in the field and to collect raw data Our office software fully supports the collected GG04 plus data either to review and adapt or to post process col lected raw data The setting for the GG04 plus smart antenna can be adjusted with different provided tools 2 4 Power Concept Use the batteries chargers and...

Page 18: ...ositions Configure the smart antenna Collect raw data from the smart antenna Collect live data Configure RTK connections to improve positioning accuracy Export collected data in different formats Refer to the respective software documentation for further information A Leica Zeno Connect license is already included with the GG04 plus in order to use the antenna on Android iOS moblile devices smartp...

Page 19: ... C 50 F to 68 F if possible It is normal for the battery to become warm during charging Using the chargers recommended by Leica Geosystems it is not possible to charge the battery once the temperature is too high For new batteries or batteries that have been stored for a long time three months it is effectual to make only one charge discharge cycle For Li Ion batteries a single discharging and cha...

Page 20: ...ock the battery compartment by pushing the slide fastener in the direction of the arrow with the close lock symbol 3 3 Equipment Setup as a Real Time Rover 3 3 1 Setup with Leica Zeno GIS Hardware and Software The equipment setup is used for real time rover with extended periods of use in the field This chapter shows a possible pole setup with Leica Zeno GIS hardware and software Connection betwee...

Page 21: ...g the locking pin into the locked position 4 Insert the battery into the field controller 5 Press the ON OFF key on the field controller to switch on 6 Insert the battery into the GG04 plus 7 Press the ON OFF key on the GG04 plus to switch on 8 Screw the GG04 plus to the top of the pole 9 Start the Zeno GIS software on the controller and select the GG04 plus instrument to be connected through Blue...

Page 22: ... GG04 plus b GEB212 battery c Pole d Mobile device e UVPMLPH Universal Pole Mount large Smartphones Step Description 1 Attach the correct pole holder depending on the mobile device to the pole clamp 2 Clip the mobile device into the pole holder 3 Switch on the mobile device 4 Download and install Zeno Connect from the repective app store or from myWorld 5 Start the Zeno Connect app 6 Insert the ba...

Page 23: ... accurate position achievable with the GG04 plus antenna can be utilized by location aware applications running on iOS Android or Windows 015190_001 There are three different versions of Zeno Connect available One for iOS one for Android and one for Windows Zeno Connect for iOS and Android is available for download from the respective app stores A valid internet connection is necessary Unlike the ...

Page 24: ...erifies that it is set as the mock location app This setting has to be enabled only once It can be achieved by following these steps Enable Mock Location Activate the Developer options first in order to enable mock locations 1 Tap OK to enter the Android settings page when Zeno Connect is asking for it 2 Scroll to and tap About phone in the Settings page 3 Scroll to and tap Build number seven time...

Page 25: ...r the pairing code 0000 once requested In case Zeno Connect is not yet installed on the Apple device a pop up is displayed It guides you auto matically to the Zeno Connect installation from the Apple App Store iOS Start Zeno Connect to configure and to provide correction data to the antenna The high accuracy position is then automatically used by any location aware app running on the Apple device ...

Page 26: ... Lite service The convergence phase can take up to 30 minutes to have a converged solu tion with the Spot Prime option and up to seven minutes for Spot Lite An L1 L2 option is necessary to use the different Spot options After ordering the subscription service activate the respective Spot option once within 30 days of the order date To complete the activation process switch on the antenna and leave...

Page 27: ...o 5 Technical Data for information about storage temperature range Remove batteries from the product and the charger before storing After storage recharge batteries before using Protect batteries from damp and wetness Wet or damp batteries must be dried before storing or use A storage temperature range of 0 C to 30 C 32 F to 86 F in a dry environment is recommended to minimize self discharging of ...

Page 28: ...tment Do not repack until everything is dry Always close the container when using in the field 12542_002 Keep plugs clean and dry Blow away any dirt lodged in the plugs of the con necting cables Cables and plugs 28 Care and Transport ...

Page 29: ...eo E6 will be provided through future firmware upgrade Cold start s Warm start s 40 30 1 s 5 2 Accuracy Accuracy is dependent upon various factors including the number of satellites tracked constellation geometry observation time ephemeris accuracy iono spheric disturbance multipath and resolved ambiguities The following accuracies given as root mean square are based on measure ments processed usi...

Page 30: ...g RTK L1 L2 1 cm 1 ppm Measurement precision accuracy and reliability depend upon various factors including number of available satellites geometry proximity to base station multipath effects or ionospheric conditions Type Accuracy RTK L1 L2 2 cm 1 ppm Measurement precision accuracy and reliability depend upon various factors including number of available satellites geometry proximity to base stat...

Page 31: ...Typically 2 dB Operating temperature C Storage temperature C 40 65 Bluetooth 30 65 40 80 External influences Protection Water dust and sand IP68 IEC60529 Protected against continuous immersion in water Tested for 2 hours in 1 40 m depth Dust tight Humidity Up to 100 Periodically drying out the instrument effectively coun teracts the effects of con densation Description Default setting Baud rates 4...

Page 32: ...art 15 or European directive 1999 5 EC has to be approved prior to use and operation Japanese Radio Law and Japanese Telecommunications Business Law Compliance This device is granted pursuant to the Japanese Radio Law 電波法 and the Japanese Telecommunications Business Law 電気通信事業法 This device should not be modified otherwise the granted designa tion number will become invalid Type Frequency band MHz ...

Page 33: ...must do so in accordance with the IATA Dangerous Goods Regulations Leica Geosystems has developed Guidelines on How to carry Leica products and How to ship Leica products with Lithium batteries Before any transportation of a Leica product we ask you to consult these guidelines on our web page http www leica geosystems com dgr to ensure that you are in accordance with the IATA Danger ous Goods Regu...

Page 34: ...ogether with all products and can also be referred to and downloaded at the Leica Geosystems home page at http leica geosystems com about us compliance standards legal documents or collected from your Leica Geosystems distributor You must not install or use the software unless you have read and accepted the terms and conditions of the Leica Geosystems Software Licence Agree ment Installation or us...

Page 35: ...atest firmware version Refer to the corresponding software documentation on how to connect the instrument to your device and how to use Leica Zeno GIS Tools Upgrading system firmware GG04 plus firmware can only be uploaded from a Windows computer or laptop Step Description 1 Download the most recent GG04 plus firmware from https myworld leica geosystems com 2 Download the Leica Zeno FW loader from...

Page 36: ...unction Direction 1 USB_D USB data line In or out 2 USB_D USB data line In or out 3 GND Signal ground 4 RxD RS232 receive data In 5 TxD RS232 transmit data Out 6 ID Identification pin In or out 7 PWR Power input 10 5 V 28 V In 8 TRM_ON USB_ID RS232 general purpose signal In or out 8 pin LEMO 1 LEMO 1 8 pin LEMO EGI 1B 308 CLN Description Port at the instru ment underside Pin assignments for 8 pin ...

Page 37: ......

Page 38: ...systems AG Heinrich Wild Strasse CH 9435 Heerbrugg Switzerland Phone 41 71 727 31 31 www leica geosystems com 123456 1 0 0en Original text Published in Switzerland 2017 Leica Geosystems AG Heerbrugg Switzerland ...