Model 8075E Operations Manual v7.21
20
Write Mode Command, Smart Antenna Reader Integer Mode “Scanner Out”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Not Used, Write With Zeros
1
0
1
Toggle
Address
Not Used
Smart Antenna Address
DATA 0
Not Used
New Write Mode Value
DATA 1
Not Used, Write With Zeros
DATA 2
DATA 3
Response “Scanner In”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Data Type Bits
ERROR Bits
1
0
1
Toggle
Address
Not Used
Smart Antenna Address
DATA 0
Not Used, Unmodified
New Write Mode Value
DATA 1
Not Used, Unmodified
DATA 2
DATA 3
ERROR Bits:
00 = Successful Command, New Write Mode Set
01 = Failure to Set new Write Mode
10 = No Response from Read/Write Head
View Write Mode Command, Smart Antenna Reader Integer Mode “Scanner Out”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Not used, Write with Zeros
1
1
0
Toggle
Address
Not used
Smart Antenna Address
DATA 0
Not Used, Write With Zeros
DATA 1
DATA 2
DATA 3