Response: OK
Example: [5=255.255.255.0] Set new subnet mask
[6=Gateway]
Format: 6=NNN.NNN.NNN.NNN
Response: OK
Example: [6=10.0.1.1] Set new gateway
[7]
Format: 7 = Get IP settings
Response:
IP=10.0.1.42
Mask=255.255.255.0
Gateway=10.0.1.1
Example: [7] Request IP settings
[S]
(default operating mode)
This command changes the data output mode to SINGLE on the PROFINET connection, meaning a
Tag will be read and reported one time.
Format: S = Single Mode
Response: OK
Example: [S]
[SC]
This command changes the data output mode to SINGLE on the Serial connection.
Format: SC = Single Mode
Response: OK
Example: [SC]
[P]
This command changes the data output mode to POLLING on the PROFINET connection. Use [TAA]
command below to poll.
Format: P = Polling Mode
Response: OK
Example: [P]
[PC]
This command changes the data output mode to POLLING on the Serial connection. Use [TAA]
command below to poll.
Format: PC = Polling Mode
Response: OK
Example: [PC]