Single Mode Command, Smart Antenna Reader Integer Mode “Scanner Out”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Not Used, Write With Zeros
0
1
0
Toggle
Address
Not Used
Smart Antenna Address
DATA 0
Not Used, Write With Zeros
DATA 1
DATA 2
DATA 3
Response “Scanner In”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Data Type Bits
ERROR Bits
0
1
0
Toggle
Address
Not Used
Smart Antenna Address
DATA 0
Not Used, Unmodified
DATA 1
DATA 2
DATA 3
ERROR Bits:
00 = Successful Command
10 = No Response from Read/Write Head
Polling Mode Command, Smart Reader Antenna Integer Mode “Scanner Out”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Not Used, Write With Zeros
0
1
1
Toggle
Address
Not Used
Smart Antenna Address
DATA 0
Not Used, Write With Zeros
DATA 1
DATA 2
DATA 3