![background image](http://html1.mh-extra.com/html/rf-innovations/rfi-9256/rfi-9256_operation-manual_1450024068.webp)
H A Y E S A T C O M P A T I B L E C O M M A N D S E T
©
©
©
© RF Innovations Pty Ltd, 1998
Page: 66
223889, Revision 2.2
ATS
83 Set Auxiliary I/O Power-up Default
Range: 0x00-0xFF (0-255)
Default: 0x00
Get/Set the power defaults for the 8 bit auxiliary I/O port.
ATS
84 Set Auxiliary I/O Sample Timer
Range: 8-5000 ms
Default: 500 ms
Get/Set the sample timer for the 8 bit auxiliary I/O Port sample timer.
ATS
90 Set DCD control
Range
Description
0
ONLINE controls DCD
1
NETWORK LINK controls DCD
2
CARRIER DETECT controls DCD
3
Remote DSR controls DCD
4
Local DSR controls DCD
5
Remote CTS controls DCD
6
Local CTS controls DCD
7
DCD Always ON
8
DCD Always OFF
9
DCD disabled
Sets the DCD Control of a Serial Port.
Default:
0