I N S T A L L A T I O N
©
©
©
© RF Innovations Pty Ltd, 1998
Page: 8
223889, Revision 2.2
3
Installation
asic steps can achieve a connection straight away but, if you require a more comprehensive setup
then the information in the main data manual should be read. However, it is recommended that
you set up a simple connection to gain familiarization with the units and their internal menu system.
Setting up for a connection
The following steps should be followed for setting up communication between a pair of wireless data
transceivers received from the factory with factory default settings:
Connect the Main Ports of each radio modem to a serial port of a computer or device, using a suitable
cable
1
.
Run a suitable terminal package
2
or emulator (on the computer) using the following settings:
Communications Settings (RS-232 Com Port)
Baud Rate:
19200
Data Bits:
8
Parity:
None
Stop Bits:
1
Flow Control:
No Flow
Terminal Settings
Emulator Mode:
None or Standard TTY
Local Echo:
off
LF to CR on incoming:
off
LF to CR on outgoing:
off
Fasten the correct type of antennas, as required, to the modems ensuring they are properly seated.
Make one of the modems a Master (by default they are Slave) and set its Rx address
(modem’s
number)
by doing the following:
Connect the Local modem’s Auxiliary Port to a COM port of a terminal.
Hold Mode Select Button on the front panel of the unit to select Mode 6 – config.
This will bring up the Configuration Menu on the terminal.
Press ‘R’ to select the “
Radio Configuration Menu
”.
Press ‘M’ to set the unit to a Master.
Press ‘L’ to set the Local Rx Address (modem’s number)
Press ‘Esc’ (escape) twice.
Press ‘Y’ to exit the Menu.
At this point a Network Link will be established, and the Slave modem will have the
N
ETWORK
L
INK
and
C
ARRIER
D
ETECT
LEDs activated and the
P
OWER
LED Flashing. The Master will only have a Flashing
P
OWER
LED.
1
using an RFI pre-made cable [optional] or by a user constructed cable in accordance to the pin configuration in Technical Specifications
2
If you don’t have a terminal program that can be set to 19200 baud, you can download our shareware terminal program (RFI’s InTerm) from the RF
Innovations Web site (
http://www.rfinnovations.com.au/
).
B
Содержание RFI-9256
Страница 1: ...RF INNOVATIONS PTY LTD RFI 9256 OPERATION MANUAL ...
Страница 2: ......
Страница 6: ......
Страница 106: ...G L O S S A R Y RF Innovations Pty Ltd 1998 Page 104 223889 Revision 2 2 ...
Страница 107: ...B L A N K P A G E RF Innovations Pty Ltd 1998 Page 105 223889 Revision 2 2 ...