H A Y E S A T C O M P A T I B L E C O M M A N D S E T
©
©
©
© RF Innovations Pty Ltd, 1998
Page: 63
223889, Revision 2.2
ATS
41 Number of retries for ARQ
Range: 0-255
Default: 50
Set the number of retries ARQ Link control parameter.
ATS
42 Network fail timeout
Range: 100-30000 ms
Default: 5000 ms
Set the Network fail timeout parameter.
ATS
43 Online requests timer
Range: 0-30000 ms
Default: 1000 ms
Set the Online request timer parameter.
ATS
44 Hopping Pattern Sequence
Range: 0-31
Default: 0
Set the Hopping Pattern Sequence parameter.
ATS
45 Max TX Power
Range: 0,10,20,25,30 dBm
Default: 20 dBm
Set the Maximum Transceiver output power parameter.
ATS
47 Frame Time
Range: (5),8,10,15,20,25,30,35 ms Default: 20 ms
Set the Frame Time parameter