4-44
Technical Data
Rexroth IndraDyn A
4.14 Technical Data Sheet for MAF100C
Description
Symbol
Unit
MAF100C
Motor data
1
)
Winding
0050
0100
0150
0200
0250
Rated torque
M
nenn
Nm
70
68
66
64
62
Rated speed
n
nenn
rpm
500
1000
1500
2000
2500
Rated power
P
nenn
kW
3.9
7.5
10.4
13.4
16.2
Rated current
I
nenn
A
12.1
19
27.9
36.7
40.2
Continuous torque at standstill
M
n1
Nm
-
70
68
66
64
Derating speed
n
1
rpm
-
500
1000
1500
2000
Continuous current at standstill
I
n1
A
-
19.5
28.6
37.6
45
Maximum speed
M
max
Nm
154
154
149
145
138
Torque constant at 20°C
K
M_nenn
Nm/A
6.06
3.77
2.5
1.91
1.55
Min. cross section of power cable
2
)
A
mm²
2.5
2.5
4
6
10
Number of pole pairs
p
3
Moment of inertia of rotor
3
)
J
rot
kgm²
0.0284
Mass
3
)
m
kg
70
- Standard
n
max
rpm
3000
6000
9000
- coupling attachment
n
max
rpm
3000
6000
6300
- reinforced
n
max
rpm
not available
Maximum
speed with
bearing...
- High-speed
n
max
rpm
3000
6000
9000
11000
6
)
Thermal time constant
T
th
min
10
Duty cycle time (S6-44%)
T
C
min
i.p.
Noise level
4
)
p
Schall
dB(A)
70 (+3)
Permissible ambient temperature
T
um
°C
0....+40
Permissible storage and transport
temperature
T
lager
°C
-20....+80
Insulation class according to
DIN VDE 0530-1
F
International Protection class
IP65
Liquid cooling
5
)
Power loss to be dissipated
P
V
kW
1.1
1.2
1.3
1.9
Cooling agent inlet
T
ein
°C
+10....+40
Cooling agent
temperature
Permissible increase at P
V
∆
T
diff
K
10
without fast coupling
∆
p
diff
bar
0.6
Decompres-
sion at Q
min
with fast coupling
∆
p
diff
bar
1.2
Required flow of coolant at P
V
Q
min
l/min
1.6
1.75
1.9
2.8
Permissible inlet pressure
p
max
bar
3
Holding brake (optional)
Electrically-clamped
Electrically-released
Transmittable torque
M
4
Nm
30
24
Connection voltage
U
Br
V
DC 24 ± 10 %
Rated current
I
Br
A
0.9
1.1
Moment of inertia
J
Br
kgm²
0.00056
Max. permissible braking energy
W
max
Ws
20000
Disengagement time
t
2
ms
50
90
Engagement time
t
1
ms
42
30
Maximum speed of brake
n
Br_max
rpm
10000
10000
Mass
m
kg
2
1.6
1
)
Values determined according to IEC 60034-1. Current and voltage specified as root-mean-square values.
2
)
Rated for cable assemblies with current carrying capacity according to VDE0298-4 (1992) and installation type B2
according to EN 60204-1 (1993) at 40°C ambient temperature.
3
)
Values without holding brake.
4
)
in 1 m distance, with PWN = 4kHz
5
)
Data refer to water as a cooling agent. If using other coolant, re-calculate the data.
Observe instructions on coolant inlet temperature in chapter 9.
6
)
Value is without a holding brake. This value may be limited by a holding brake.
Fig. 4-67:
Data sheet MAF100C
Содержание IndraDyn A Series
Страница 8: ...VI Table of Contents Rexroth IndraDyn A...
Страница 12: ...1 4 Introduction to the Product Rexroth IndraDyn A...
Страница 26: ...3 12 Safety Instructions for Electric Drives and Controls Rexroth IndraDyn A Notes...
Страница 102: ...4 76 Technical Data Rexroth IndraDyn A...
Страница 140: ...6 20 Type Codes Rexroth IndraDyn A...
Страница 144: ...7 4 Accessories Rexroth IndraDyn A...
Страница 194: ...9 38 Application Notes Rexroth IndraDyn A...
Страница 198: ...10 4 Handling and Transportation Rexroth IndraDyn A...
Страница 219: ......