F382 Mains phase loss fault
With HVE only !
Cause:
At least one phase of the 3 pjase power supply input is missing.
Remedy:
Check mains fuses and replace, if necessary.
F383 Line voltage fault
With HVR only !
Cause:
Mains voltage exceeds permissible tolerance (3x 380 ... 480V,
±
10 %).
Remedy:
Check mains voltage, use matching transformer, if necessary.
F384 Connection error at power supply unit
With HVR only !
Cause:
Power and control voltage connects are not in phase.
Remedy:
Check connection voltage. Terminals X5/U and X8/1, X5/V and X8/2,
X5/W and X8/3 may not conduct voltage to each other.
F385 Line frequency fault
With HVR only !
Cause:
Mains frequency exceeds permissible tolerance (
±
2Hz).
F394 Checksum error power supply unit
With HVR only !
Cause:
Unit failure.
Remedy:
Replace unit.
F401 Double MST failure shutdown
The master sync telegram was not received in the drive controller in two
successive SERCOS cycles.
Содержание DIAX04
Страница 4: ...About this Documentation DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Страница 14: ...1 4 Diagnostic Message Descriptions DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Страница 28: ...3 12 Safety Instructions for Electric Drives and Controls DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Страница 68: ...4 40 Description of Diagnostic Letters F and E DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Страница 104: ...5 36 Description of diagnostic letters F and E DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P Notes...
Страница 106: ...6 2 Index DIAX04 ELS 06VRS DOK DIAX04 ELS 06VRS WA01 EN P W Warning symbols 3 1...
Страница 113: ......
Страница 114: ...Printed in Germany 2 9 1 6 2 8...