MAN-000020-00 REV A
35
Possible Causes
Blocked air flow to the charger.
Failed cooling fan.
Room temperature above 104
˚F.
Troubleshooting
a. Select
STOP
to revert to the
Connect Battery
or
Push START
screens.
b. Allow the charger to cool down.
c. Make sure there are no airflow restrictions to the intake or exhaust of the
charger.
d. Restart the charge cycle by selecting
START
.
e. If the fault persists, contact the Dealer or Power Designers USA LLC.
5. Charger Timeout Faults
The
screen
indicates which timer has caused the problem:
TRICKLE CHARGE
,
CC CHARGE
, or
CV CHARGE
.
Possible Causes
Programmed charge timers are set incorrectly.
Programmed charge parameters are set incorrectly.
Battery has shorted cell(s).
Troubleshooting
a. Select
STOP
to revert to the
Connect Battery
or
Push START
screens.
b. Verify that the battery is in good working condition (i.e., no shorted cells).
c. If the fault persists, contact the Dealer or Power Designers USA LLC.