MAN-000020-00 REV A
25
NOTE: Once an Equalization is activated, it remains active until an
equalization cycle has completed.
d. Press
ENTER
key to save selection and return to the main menu. The LCD
display now indicates the Equalization charge is activated with an “E” in the
upper right corner of the display, and one of the following displays will be
observed, depending on the setup of the Charger.
2. Desulfation Cycle
One of the unique features of this charger is the ability to run a safe, tailored
recovery cycle for sulfated batteries. This can easily be done through the
DESULFATION CYCLE
screen.
a. Connect the battery to be recovered. If the charger is set to auto-start the
charge cycle, press the stop button until you are back on the “Push Start”
screen.
NOTE: Do not attempt to recover a battery with a capacity of less than 250
amp-hours.