134
Intera 3.2
Signals
•
To disable an existing signal, select none in the spin box next to the signal, then
return with the Back button. This removes the association of the signal from the
current action, subtask, or at the task level, but the signal itself remains available,
so it can be associated to other actions, subtasks, or at the task level.
•
Internal signals default names all begin with INT. (e.g. INT Ready 1)
•
As of Intera 3.2, the designation Torso is now Robot, and default names all begin
with Robot. (e.g. Robot, Ready). As a reminder, Baxter has a single input and a
single output accessible through the robot’s Db15 port.
•
The "Reset Count" policy for a Ready signal can be set to never, and you can
separately assign a Reset Count signal, if needed.
READY SIGNAL: CONFIGURE AS GATE OR ENABLE
For pick and place actions with a Ready signal, you have the option of instructing Baxter what to do
if a signal that was true when Baxter started the action becomes false. For example, in the case of
using a part present signal, if the part disappears (and the signal is false), you can choose whether
you want Baxter to continue moving or to stop.
•
If Enable is chosen for the signal, and the part present signal disappears (turns
false), Baxter will stop, go back to its approach, and wait for the signal to be true
before trying again.
Содержание Baxter
Страница 1: ...user guide for intera 3 2 software ...
Страница 7: ...5 Intera 3 2 Contents Appendix G Safety Mats 177 Appendix H Support Warranty 179 ...
Страница 100: ...98 Intera 3 2 Hold ...
Страница 108: ...106 Intera 3 2 Nudge You cannot nudge transit waypoints You can use the Navigator on either arm when in Nudge mode ...
Страница 118: ...116 Intera 3 2 Robot Positioning System 3 Select Create New ...
Страница 180: ...178 Intera 3 2 Note Unless shown as a jumper in the above diagram all other wiring is pin for pin on each connector ...
Страница 182: ......
Страница 183: ...Last updated April 17 2015 P N 26004 Rev C ...