1.2.4 Sensors
+
OK / Set
-
!
GND
S1
S2
S3
S4
S5
S7
S6
S8
CS10
Sensors
L N
L'
R7-A
R7-M
R7-R
floating relay
R3
R2
R1
semiconductor
Bus
VBus
S9
S10
R6
R5
R4
1 (1) A (100 ... 240) V~
4 (1) A (100 ... 240) V~
R1-R6
R7
V40
DIn
T4A
IP 20
Vor Öffnen Gerät spannungslos
schalten!
Isolate mains before removing cover!
Masse-Sammelklemme benutzen
Use ground common terminal block
Erdungsleiter-Sammel-
klemme benutzen!
Use ground common
terminal block!
Neutralleiter-
Sammelklemme benutzen!
Use neutral conductor
collective block!
Netz / Mains 100 ...
240
V~
50-60 Hz
N
Made in Germany
DeltaSol E
®
ground-common terminal block
The controller is equipped with 13 sensor inputs in total.
The ground connection for the sensors has to be carried
out via the ground terminal block (GND).
• Connect the
Temperature sensors
to the terminals
S1 ... S10 and GND (either polarity)
• Connect the
irradiation sensor (CS10)
to the termi-
nals CS10 and GND with correct polarity. Connect the
terminal GND of the sensor to the terminal GND of the
controller (ground terminal block), and the terminal CS
of the sensor to the terminal CS10 of the controller.
• A
flowmeter
V40 can be connected to the termi-
nals V40/DIN and DGND (either polarity).
Or an
external message signal
can be connected
to the terminals V40/DIN and DGND. When the signal
contact closes the input Din, the message “!message
ext.” is generated. This signal is treated like an error,
which means that the control lamp flashes red and the
message relay is possibly energized.
1.2.5 Power supply
Connecting the device to the power supply must always be
the last step of the installation!
The power supply to the controller must be carried out via
an external power switch and the supply voltage must be
100-240 V~. Flexible cables must be attached to the housing
with the enclosed strain relief and the corresponding screws
or be run into the controller housing in a cable conduit or
trunking .
grounding conductor PE (common terminal block)
neutral conductor N (common terminal block)
conductor L
D e lt a S o l
®
E
© RESOL 10306_DeltaSol_E.mon