English 19

 

 

Symbols 

The following symbols may appear on the product or packaging. 

 

 Read instructions before use. 

 Indicates a warning or caution. 

 Follow instructions before 

use. 

 Manufacturer. 

 European Authorized Representative. 

 Batch code. 

 Catalog number. 

 Serial number. 

 Device number. 

 On / Off.   Device weight. 

 Protected against finger sized objects and against dripping water when tilted up to 15 degrees 

from specified orientation. 

 Direct current. 

 Type BF applied part. 

 Class II equipment. 

 Humidity limitation. 

 Temperature limitation. 

 Non-ionising radiation. 

 China pollution 

control logo 1. 

 China pollution control logo 2. 

 Prescription only (In the US, Federal 

law restricts these devices to sale by or on the order of a physician). 

 Maximum 

water level. 

 Use distilled water only. 

 Operating altitude. 

 Atmospheric pressure 

limitation. 

 Complies with RTCA DO-160 section 21, category M. 

 

 

Environmental information

 

This device should be disposed of separately, not as unsorted municipal waste. To dispose of your 
device, you should use appropriate collection, reuse and recycling systems available in your region. 
The use of these collection, reuse and recycling systems is designed to reduce pressure on natural 
resources and prevent hazardous substances from damaging the environment. 

If you need information on these disposal systems, please contact your local waste administration. 
The crossed-bin symbol invites you to use these disposal systems. If you require information on 
collection and disposal of your ResMed device please contact your ResMed office, local distributor 
or go to www.resmed.com/environment. 

 

Servicing 

The AirSense 10 device is intended to provide safe and reliable operation when operated in 
accordance with the instructions provided by ResMed. ResMed recommends that the AirSense 10 
device be inspected and serviced by an authorized ResMed Service Centre if there is any sign of 
wear or concern with device function. Otherwise, service and inspection of the products generally 
should not be required during their design life. 

 

Limited warranty 

ResMed Ltd (hereafter 'ResMed') warrants that your ResMed product shall be free from defects in 
material and workmanship from the date of purchase for the period specified below. 

Product Warranty 

period 

 

Mask systems (including mask frame, cushion, headgear and tubing)—excluding 
single-use devices 

 

Accessories—excluding single-use devices 

 

Flex-type finger pulse sensors 

 

Humidifier water tubs 

90 days

 

Batteries for use in ResMed internal and external battery systems 

6 months

Содержание AirSence 10

Страница 1: ...User guide English User guide...

Страница 2: ...e AirSense 10 Elite device is indicated for the treatment of obstructive sleep apnea OSA in patients weighing more than 30 kg It is intended for home and hospital use The humidifier is intended for si...

Страница 3: ...es available for use with the device including Air tubing heated and non heated ClimateLineAir SlimLine Standard Filter Hypoallergenic filter standard filter Air10 DC DC converter SD card reader Air10...

Страница 4: ...o select an option Turn to adjust a selected option and press to save your change Home button Press to return to the Home screen Different icons may be displayed on the screen at different times inclu...

Страница 5: ...end into the power outlet 3 Connect the air tubing firmly to the air outlet located on the rear of the device 4 Open the humidifier and fill it with water up to the maximum water level mark Do not fil...

Страница 6: ...restored The AirSense 10 device has a light sensor that adjusts the screen brightness based on the light in the room Stopping therapy 1 Remove your mask 2 Press Start Stop or if SmartStart is enabled...

Страница 7: ...nning of therapy more comfortable Ramp Time is the period during which the pressure increases from a low start pressure to the prescribed treatment pressure You can set your Ramp Time to Off 5 to 45 m...

Страница 8: ...rts blowing air 3 Adjust the mask mask cushion and headgear until you get a Good result To stop Mask Fit press the dial or Start Stop If you are unable to get a good mask seal talk to your care provid...

Страница 9: ...sk then gently pull apart Cleaning You should clean the device weekly as described Refer to the mask user guide for detailed instructions on cleaning your mask 1 Wash the humidifier and air tubing in...

Страница 10: ...lockages by dirt or dust To replace the air filter 1 Open the air filter cover and remove the old air filter The air filter is not washable or reusable 2 Place a new air filter onto the air filter cov...

Страница 11: ...s not in Airplane Mode Notes Therapy data might not be transmitted if you use it outside of the country or region of purchase Devices with wireless communication might not be available in all regions...

Страница 12: ...rplane Mode To turn on Airplane Mode 1 In My Options turn the dial to highlight Airplane Mode and then press the dial 2 Turn the dial to select On and then press the dial to save the change The Airpla...

Страница 13: ...ed I have stopped therapy but the device is still blowing air Device is cooling down Device blows a small amount of air in order to avoid condensation in the air tubing It will stop automatically afte...

Страница 14: ...Air tubing may be blocked Check the air tubing and remove any blockages Press the dial to clear the message and then press Start Stop to restart the device SD card error remove your card and press St...

Страница 15: ...d into the pivot hole of the base 2 Slide the other side down the ridge until it clicks into place General warnings and cautions WARNING Make sure that you arrange the air tubing so that it will not t...

Страница 16: ...omeone is likely to trip over the power cord Blocking the air tubing and or air inlet of the device while in operation could lead to overheating of the device Keep the area around the device dry clean...

Страница 17: ...otection IP22 Sensors Pressure sensor Internally located at device outlet analog gauge pressure type 5 to 45 cm H2O 5 to 45 hPa Flow sensor Internally located at device inlet digital mass flow type 70...

Страница 18: ...operation Not applicable to masks tubes or accessories Operating pressure range AutoSet CPAP 4 to 20 cm H2O 4 to 20 hPa Supplemental oxygen Maximum flow 4 L min Pneumatic flow path 1 Flow sensor 2 Blo...

Страница 19: ...o 150 L min positive flow Leak2 12 L min or 20 of reading whichever is greater 0 to 60 L min 1 Results are expressed at ATPD Ambient Temperature and Pressure Dry 2 Accuracy may be reduced by the prese...

Страница 20: ...reduce pressure on natural resources and prevent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The...

Страница 21: ...eing spilled on or into an electronic device Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consume...

Страница 22: ...ee Ave Milton Park Abingdon Oxfordshire OX14 4RW UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip Air10 AirSense AutoSet ClimateLine HumidAir and...