3.13
System
installation
RMI-QE cable
Cable termination
A ferrule should be crimped onto each cable wire for a more positive connection at the terminal box.
Standard cable variants
The RMI-QE standard cables are 8 m (26.2 ft) and 15 m (49.2 ft) long.
Cable specification
Ø6.1 mm (0.24 in), 16-core screened cable, each core 28 AWG.
NOTE:
Maximum cable length:
30 m (98.42 ft) at 12 V
50 m (164.04 ft) at 24 V
Cable sealing
Coolant and dirt are prevented from entering the RMI-QE by the cable sealing gland. The RMI-QE
cable can be protected against physical damage by fitting a flexible conduit if required.
Recommended flexible conduit is Anamet™ SLI-CAP (5/16 in).
A conduit set is available – see Section 6,
“Parts list”
, for further information.
CAUTIONS:
Failure to adequately protect the cable can result in system failure due to either cable damage or
coolant ingress through cores into the RMI-QE.
Failure due to inadequate cable protection will invalidate the warranty.