3.7
System
installation
Wiring diagram
(with output groupings shown)
12 V to 30 V
Turquoise
Violet
Green
Turquoise/black
Violet/black
Green/black
White
Pink
White/red
Brown
Yellow
Signal
Return
(see note)
Orange
Red
Black
Green/yellow
Grey
White/blue
RMI-QE with hard-wired cable
Machine ground (“star point”)
Power supply (12 V to 30 V)
Error (SSR) (see notes)
Probe status 1 (SSR)
Low battery (SSR) (see notes)
Machine start input [P1]
Machine start input [P2]
Machine start input [P3]
Machine start input [P4]
Machine start return
Probe status 2b
CAUTION:
The power supply 0 V should be terminated at the machine ground (“star point”).
A negative supply can be used when wired appropriately.
Driver
Screen
Driver
Probe status 2a
(5 V isolated driven skip)
5 V
0 V
NOTES:
A s
witch can be fitted between the machine power supply and the red wire, to aid powering up the
RMI-QE when partnering.
It is recommended that both the low battery (SSR) and error (SSR) are connected to provide full
system information.
}
}
}
}
}