M3028BT2-CPE User’s Manual
4. Hardware Specifications
REJ10J1457-0300 Rev.3.00 July 22, 2009
Page 78 of 90
4.5 Notes on Using This Product
Notes on using this product are listed below. When debugging the MCU using this product, be careful about the following
precautions.
IMPORTANT
Note on the Version of the Emulator Debugger:
z
Be sure to use this product with one of the following emulator debuggers.
M16C R8C Compact Emulator debugger V.1.02 Release 00 or later
When debugging the M16C/26A Group MCUs, an MCU file for the M16C/26A and M16C/26B
(M16C26.MCU) is required.
When debugging the M16C/28 Group MCUs, an MCU file for the M16C/28 and M16C/28B
(M16C28.MCU) is required.
When debugging the M16C/29 Group MCUs, an MCU file for the M16C/29 (M16C29.MCU) is required.
Notes on the Self-check:
z
If the self-check does not result normally (excluding target status errors), the emulator may be damaged. Then
contact your local distributor.
z
Run the self-check with the user system not connected.
Note on Quitting the Emulator Debugger:
z
To restart the emulator debugger, always shut power to the emulator module off once and then on again.
Notes on the User System (Power Supply, Order of Powering On):
z
When the user system is connected, be sure to set the JP1 of the emulator to "EXT".
z
This emulator cannot supply the power to the user system. Therefore design your system so that the user system
is powered separately.
z
This emulator consumes max. 500mA of electric current from the user system.
z
The voltage of the user system should be as follows.
2.7
V
≤
VCC
≤
5.5 V
z
Do not change the voltage of the user system after turning on the power.
z
Before powering on your emulator system, check that the host machine, the emulator, the converter board and
user system are all connected correctly. Next, turn on the power to each equipment following the procedure
below.
(1) Turn ON/OFF the user system and the emulator as simultaneously as possible.
(2) When the emulator debugger starts up, check the target status LEDs on the emulator to see if this product
is ready to operate.
Is the power supplied? Check that target status LED (POWER) is ON.*1
Is the clock supplied? Check that target status LED (CLOCK) is ON.
*1 When the user system is not connected the target status LED (POWER) does not light.