M3028BT2-CPE User’s Manual
2. Setup
REJ10J1457-0300 Rev.3.00 July 22, 2009
Page 41 of 90
(2) Using an Oscillator Circuit on the User System
To operate this product with an external clock, construct an oscillator circuit as shown in Figure 2.20 in the user system and
input the oscillator output at 50% duty (within the operating range of the evaluation MCU) into pin X
IN
. And pin X
OUT
should
be open. Choose "External" in the emulator debugger to use this clock.
Figure 2.20 External oscillator circuit
Make note that in the oscillator circuit shown in Figure 2.21 where a resonator is connected between pins X
IN
and X
OUT
,
oscillation does not occur because a converter board and other devices are used between the evaluation MCU and the user
system. It is same for sub-clock oscillator circuits (X
CIN
and X
COUT
).
Figure 2.21 Circuit in which oscillation does not occur