4
IV. Maintenance
(continued)
fig. 35
fig. 36
9. Rotate the flow-meter knob
clockwise until the notch on
the label aligns with the white
indicator on the flow-meter
body(see figure 35). You should
have marked the 1/2 box when
resetting your flow meter at the
half life (see page 27
Replacing
Components
) (Apply the new
label if supplied with your new
multi-media filter by aligning
the notch on the label with the
indicator on the flow-meter
body.) Replace the base.
10. Turn the filter upright, and
reinsert the outlet tubing
or spout into the AQUA
3
II
tubing receptacle with a white
collar and marked with a (0)
(see figure 36/36a). Engage
the diverter valve, and turn the
tap water on. Check the whole
unit for water leaks.
11. If no leaks are found, replace
the body-cover and flush for
two minutes.
Note:
If you find a leak that cannot
be corrected by re-attaching all of
the connections, contact your local
Rena Ware Customer Service
Office.
Note:
Over time, a diverter valve
may lose its lubrication and
become more difficult to operate.
To improve performance, place a
small drop of petroleum jelly (e.g.
Vaseline), or silicone grease at
the points shown.
APPLY LUBRICANT HERE,
AND ON OPPOSITE SIDE
SPOUT MODEL
DOUBLE DIVERTER VALVE
MODEL (NON SPOUT)
fig. 36a
VALVE STEM
Содержание AQUA II 5000
Страница 1: ... Use Care ...
Страница 7: ... A Q R O P L C M I N K S T U D H W B G J V F E X Z Y D ...