2.3 Performance curves for heating and cooling
Heating capacity SKT 520
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
5,00
5,50
6,00
6,50
-15
-7
-5
0
7
12
2
1
3
A
[°C]
Fig. 2: Performance curves, heating SKT 520 (data for room temperature 20 °C)
A: Outside temperature
1: COP
2: Heating capacity in kW
3: Power consumption in kW
Outside temperature in °C
-15
-7
-5
0
7
12
Heating capacity in kW
3.04
3.21
3.46
4.05
5.57
6.34
Power consumption in kW
1.30
1.32
1.35
1.41
1.54
1.57
COP
2.33
2.43
2.56
2.88
3.61
4.04
Cooling capacity SKT 520
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
4,00
4,50
5,00
5,50
6,00
6,50
21
25
30
35
40
2
1
3
A
[°C]
Fig. 3: Performance curves, cooling SKT 520 (data for room temperature FK 27°C/TK 19 °C)
A: Outside temperature
1: EER
2: Cooling capacity in kW
3: Power consumption in kW
Outside temperature in °C
21
25
30
35
40
Cooling capacity in kW
5.10
5.44
5.48
5.28
4.53
Power consumption in kW
1.36
1.47
1.60
1.75
1.78
EER
3.74
3.70
3.42
3.02
2.55