background image

Safety notes

Disposal of packaging

All products are packed for trans-
port in environmentally friendly 
materials. Make a valuable con-
tribution to reducing waste and 
sustaining raw materials. Only 
dispose of packaging at approved 
collection points. 

Disposal of units and 
components

For the manufacture of the units 
and components, only recyclable 
materials have been used.
Help protect the environment by 
ensuring that the units or compo-
nents (for example batteries) are 
not disposed in household waste, 
but only in accordance with local 
regulations and in an environmen-
tally safe manner, e.g. through 
authorised disposal and recycling 
specialists or at collection points.

Warranty

Prerequisite for any warranty claims  
is that the purchaser or his client  
has completely filled out the "war-
ranty registration card" included 
with any unit within the relevant 
time period of sale and initial op-
eration and returned it to  
REMKO GmbH & Co. KG. 
The warranty conditions are listed 
in the "General business and deliv-
ery conditions. The contractual par-
ties can also agree additional terms 
beyond the scope of the above. 
For this reason please contact your 
direct contracting partner first.

Environmental 

protection 

and recycling

Carefully read this manual before 
starting the unit for the first time. It  
contains useful tips, information as 
well as hazard warnings to prevent 
injury or material damage. Non-
observance of this manual may 
endanger persons, the environment 
as well as the equipment itself and 
will void any claims for liability.

■ 

Store this manual as well as 
the refrigerant datasheet in the 
vicinity of the unit.

■ 

The unit should only be set up 
and installed by qualified per-
sonnel.

■ 

The setup, connection and 
operation of the unit and its 
components must be in accord-
ance with the operating condi-
tions stipulated in this manual 
and comply with all applicable 
local regulations. 

■ 

Units designed for mobile use 
should be safely set up on a 
suitable floor and in a verti-
cal position. Units designed for 
stationary use should only be 
operated in their permanently 
installed state.

■ 

It is prohibited to make modi-
fications or changes to equip-
ment or components supplied 
by REMKO as this may cause 
malfunctions.

■ 

Equipment and components 
should not be operated in areas 
where there is a heightened 
damage risk. Observe the mini-
mum clearances.

■ 

The electrical supply should be 
adapted to fulfil the require-
ments of the unit.

■ 

The operational safety of equip-
ment and components is only 
assured providing they are used 
as intended and in a fully assem-
bled state. Safety devices should 
not be modified or bypassed.

■ 

Do not operate equipment or 
components with obvious de-
fects or signs of damage.

■ 

All housing parts and openings, 
e.g. air inlets and outlets, must 
not be blocked by foreign items, 
fluids or gases. 

■ 

The equipment and components 
must be kept in a safe distance 
from inflammable, explosive, 
combustible, aggressive and 
dirty areas or atmospheres.

■ 

Persons coming into contact 
with equipment parts may suffer 
burns or injury. 

■ 

Installation, repair and mainte-
nance work should only be car-
ried out by authorised special-
ists. Inspection and cleaning can 
be performed by the operator 
providing the equipment is not 
under voltage.

■ 

Take appropriate hazard preven-
tion measures when performing 
installation, repair or mainte-
nance work or cleaning the 
equipment.

■ 

The equipment or components
should not be exposed to any 
mechanical stresses, extreme 
levels of humidity or direct ex-
posure to sunlight.

REMKO RVD...DC

4

Содержание RVD 351DC

Страница 1: ...Issue D V03 REMKO RVD RVD 351DC RVD 521DC Inverter ceiling mounted air conditioner in split design Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...tion and recycling 4 warranty 4 Transport and packaging 5 Description of the equipment 5 Operation 6 12 Shutdown 13 Care and maintenance 13 14 Troubleshooting and customer service 15 16 Installation i...

Страница 4: ...stalled by qualified per sonnel The setup connection and operation of the unit and its components must be in accord ance with the operating condi tions stipulated in this manual and comply with all ap...

Страница 5: ...ant circuit with compressor fin liquefier liquefier fan reverse flow valve and flow regulator The outdoor unit is controlled via the regulation of the indoor unit The indoor unit is designed for indoo...

Страница 6: ...e manually operated Problems are shown in code see chapter Troubleshooting and Customer service CAUTION Immediately replace flat batter ies with a new set otherwise there is a risk of leakage It is re...

Страница 7: ...t LOCK button pre vents subsequent operation the right RESET button resets the display Buttons on the remote control ON OFF Button Press this button to start the unit MODE button Press this button to...

Страница 8: ...modes The nominal temperature can be preselected and is then applied in automatic mode The fan speed is automatically adapted to the given circumstances AUTOMATIC MODE COOLING or HEATING The nominal...

Страница 9: ...rns the cooling on again after a waiting period of 3 minutes COOLING mode COOLING OPERATION and In dehumidification mode the room temperature is set to 24 C Due to the low temperature of the refrigera...

Страница 10: ...n the room The inverter controller checks the difference between the adjusted target temperature and the actual room temperature In the event of a greater difference a higher cooling performance is cr...

Страница 11: ...function of the air discharge fins can be adjusted with this button The air distribution in the room is improved with the swing function In order to adjust the aim of the air discharge fins to a parti...

Страница 12: ...F TIMER ON button activation delay Activation delay TIMER OFF button switch off delay CANCEL delete timer program Switch off delay Time stored TIMER ON TIMER ADJUST TIMER ADJUST TIMER ADJUST OK TIMER...

Страница 13: ...ice life of the unit Care Ensure the indoor unit and out door component are protected against dirt mould and other deposits Clean the equipment using a damp cloth Do not use any caustic abrasive or so...

Страница 14: ...2 Turn the dirty side until it faces up 5 Any dirt can be cleaned off us ing lukewarm water and mild cleaning agents To do so turn the dirty side downward Fig 3 6 When using water allow the filter dr...

Страница 15: ...ot transmitted when in terference sources are operational Button in remote control jammed two buttons pressed at same time Does the Send symbol appear on the display Release the button only press one...

Страница 16: ...that the compres sor oil can flow back without obstruction LED Operation LED Timer LED Defrost LED Alarm Display outdoor unit Cause Required action E0 EEPROM error Check EEPROM E2 Communication error...

Страница 17: ...densation line Injection pipe Suction pipe PVC tube Selection of the installation location Interior unit The indoor unit is designed for horizontal wall installation above doors However it can also be...

Страница 18: ...ir work and facilitate optimum air distribution 500 1000 1000 1000 1000 E C B A D Air intake Air outlet All values in mm Minimum clearances Ensure a continuous and unob structed air flow from outside...

Страница 19: ...on nections to a second room or a fresh air intake are required See section Connections to Installation should only be performed by authorised spe cialists NOTE a second room or a fresh air intake 3 F...

Страница 20: ...ns NOTE Flanging tool 7 Flanging the refrigerant pipe Refrigerant pipe Deburrer 6 Deburring the refrigerant pipe 8 Correct flange shape Tighten 1 spanner Counter 2 spanner 9 Tighten the fitting Tighte...

Страница 21: ...e required to generate the vacuum is dependent on the pipe work volume of the indoor unit and the length of the refrigerant pipes This always takes at least 60 minutes Once any foreign gases and humid...

Страница 22: ...ram 4 Re assemble the unit Terminal block Control line Cover Control line from the out door unit 12 Connecting the indoor unit Connecting the outdoor com ponent Proceed as follows to connect the cable...

Страница 23: ...caps are tight after carrying out any work on the refrigerant circuit If necessary use appropri ate sealant products NOTE Functional test for cooling and heating modes 1 Remove the caps from the valv...

Страница 24: ...e 10 35 40 11 40 45 C 12 45 50 13 50 55 C 14 55 60 15 60 65 C 16 65 70 Display Temperature 15 7 5 20 5 0 C 25 2 5 30 0 C 35 2 5 40 5 0 C 45 7 5 50 10 0 C 55 12 5 60 15 0 C 65 17 5 C 70 20 0 C 75 22 5...

Страница 25: ...Steuerleiter DM Display Y G c Blau Y G CN5 GM P1 Lila Wei Netzzuleitung Innenteil Rot Wei CN4 CN11 CN5 CN7 CN9 Wei C5 Wei Schwarz Rot CN3 CN2 T1 T2 T2 T1 CN14 CN10 CN15 E Y X Schwarz Grau Gelb Schwarz...

Страница 26: ...5 CN6 CN4 CN8 CN10 CN9 Blau Ventilator CN1 CN2 L N L N P 1 L H Sensor Hei gas Sensor Au entemperatur Sensor Austritt Verfl ssiger Elektronisches Expansionsventil Leistungsplatine zum Innenger t Steuer...

Страница 27: ...dimensions and constructional design as part of the ongoing technical development process All values in mm 650 650 400 610 28 580 A D E B C RVD 351 521 DC IT RVD 351 521 DC AT RVD 351 DC RVD 521 DC A...

Страница 28: ...1110955 1110956 7 Vaporiser 1110957 1110958 8 Condensation pump cpl 1110959 1110959 9 Fan wheel 1110960 1110961 10 Vaporiser fan motor 1110962 1110963 11 Control PCB 1110964 1110965 12 Transformer 11...

Страница 29: ...alve injection pipe 1111006 1111007 10 Reverse flow valve 1111008 1111009 11 Control PCB 1111010 1111011 12 Condenser compressor 1111012 1111013 Spare parts not illustrated E Box complete 1111014 1111...

Страница 30: ...T RVD 521DC IT Adjustment range room temperature C 17 30 Operating range C 17 31 Air flow volume per speed setting m h 510 530 680 560 710 800 Sound pressure level per speed setting 3 dB A 33 37 40 37...

Страница 31: ...Notes 31...

Страница 32: ...ore than mere salespeople they must primarily act as advisers in air conditioning and heating technology for our customers Customer Service Our units work precisely and dependably Should a failure occ...