5
System Design
Transport and Packaging
The unit is shipped in a stable transport box made of
cardboard. Please examine the unit when it is delivered.
Make note of any damage or missing parts on the ship-
ping bill and notify the shipping company and your con-
tract partner.
We do not assume any liability for subsequent com-
plaints.
Operation
Manual operation
The units can be put into operation manually if, for exam-
ple, the remote control is not working properly or is not
available.
You can choose between two settings:
AUTO
HEAT (heating)
In AUTO mode, the unit
warms
the room temperature
until it reaches the set temperature of 24 °C.
COOL
(cooling)
In COOL mode, the unit
cools
the room temperature
until it reaches the set temperature of 24 °C.
1 Indoor unit RKS ... H-IT
2 Outdoor part RKS ... H-AT
3 Infrared remote control
4 Connection lines
5 Air filter
6 Air intake grille
7 Air outlet plate fins with swing motor
8 Plate fins for directing air or manually
(covered)
9 Display and receiver
10 Console for manual operation
11 Shut-off the valves
12 Condenser fan
13 Wall lead-through
14 Condensation connection RKS ... H-AT
15 Condensation connection RKS ... H-IT
11
3
4
7
8
15
9
5
Outside
Inside
2
1
14
12
10
13
6
Manual operation of RKS 327 H and RKS 335 H
The buttons for selecting the manual mode are hidden
behind the air intake grille. Press the button you want
with a suitable tool. Press the button again to deactivate
manual operation.
RKS 327 H
RKS 335 H
Manual operation of RKS 350 H and RKS 371 H
The
A
button for selecting the manual mode is hidden
behind the air intake grille. Press the button to set the
AUTO mode. Press the button again to set the Cool
mode. Press the button one more time to deactivate
manual operation.
RKS 350 H
RKS 371 H
A
A