background image

19

Spare parts list 

No. Description  

EDP no.

 1   Transport handle 

1101142

 2   Exterior cladding PGM 60  

1101420

 2a  Exterior cladding PGM 60 E  

1101461

 3   Insulation 

1101421

 4   Combustion chamber 

1101422

 5   Gas burner 

1101423

 6   Protective outlet grille 

1101424

 7   Gas nozzle 

1101426

 8   Gas supply pipe Z/D  

1101458

 9   OT elbow union  

1101316

10   Ignition electrode 

1101280

11   Ignition cable 

1101283

12   Thermocouple  

1101164

13   Support, front  

1101427

14   Unit base 

1101428

15   Inspection cover  

1101469

16   Gas supply pipe R/Z  

1101459

17   IT elbow union  

1101468

18   Safety pilot 

1101169

19   GE-screw connection 

1101359

20   Gas control 

1101412

21   Screw connection M10x1  

1101409

22   Gas supply pipe M/R  

1101441

23   Support, rear 

1101249

24   Safety temperature limiter 

1101197

26   GE-screw connection 

1101396

27   Solenoid valve 

1101376

28   Piezo igniter  

1101364

29   Gas connection nipple 

1101134

30   Adjusting knob, cpl.  

1101192

31   Strain relief 

1101267

32   Operating switch 

1101188

33   Terminal block, 6x  

1101366

34   Grommet 

1101304

35   Mains cable with plug  

1101320

36   Protective intake grille  

1101432

37   Fan motor 

1101254

38   Drive clutch B 8 ø  

1101255

39   Fan blade 

1101150

40   Retaining clip 

1101395

41   Clutch plate 

1101375

xx   Pressure controller with hose breakage protection  

1101470

xx   2 linear m. Gas hose  

1101419

xx   2 linear m. HP gas hose 

(version for construction site operation per DIN 4815 part 1, pressure class 30) 

  1101174

xx   5 linear m. HP gas hose 

(version for construction site operation per DIN 4815 part 1, pressure class 30) 

  1108410

xx   10 linear m. HP gas hose 

(version for construction site operation per DIN 4815 part 1, pressure class 30) 

 1108411

xx   Multi-cylinder set (2-3 cylinders)  

1014050

xx   T-connection for multi-cylinder set  

1101177

xx   Nylon seal for T-connection  

1101178

xx   HP hose 0.4 m for multi-cylinder set  

1101179

xx = not illustrated

When ordering replacement parts, please always state the EDP no. and unit number (see name plate)!

Содержание PGM 30

Страница 1: ...g and installation instruction This product is not suitable as a main heater Edition GB Q04 Read the instructions prior to performing any task PGM 30 E PGM 60 E REMKO PGM E series Propane gas heating...

Страница 2: ......

Страница 3: ...modifications no liability accepted for errors or misprints Safety notes 4 Unit description 5 Installation instructions 6 Gas connection 7 9 Commissioning 9 10 Shutdown 11 Care and maintenance 11 12 T...

Страница 4: ...prior to delivery However dangers can arise from the units if they are used improperly or not as intended by untrained personnel Please observe the following information The units may only be operate...

Страница 5: ...ust gas burners with thermal monitoring electric solenoid valve piezo ignition and mains cable with earthed safety plug The units are intended exclusively for manual operation and cannot be thermostat...

Страница 6: ...n well ventilated spaces and not in living areas or similar recreational areas Installation instructions The safety regulations of the accident prevention and insurance associations the respective reg...

Страница 7: ...nit connection pressure of 1 5 bar It is prohibited to exceed or undershoot the connection pressure When using longer hose lines consider the respective pressure loss Only use components that have bee...

Страница 8: ...supply tank 1 6 2 4 5 4 3 6 5 6 Attachment multi cylinder set accessory In order to ensure a regular gas take off insofar as possible all cylinder valves must be open The cylinder battery can be expa...

Страница 9: ...switch to the 0 off position 2 Connect the unit s power plug to a properly installed and fused mains socket Connect 230 V 50 Hz The units should be checked for visible defects on the operating and saf...

Страница 10: ...es 4 After a flame appears depress the pressure pin 2 for a further approx 10 15 sec until the thermal flame monitoring is activated 5 If the flame goes out when the pressure pin 2 is released repeat...

Страница 11: ...ve or solvent based cleaners Use only suitable cleaners even for heavy contamination Check the inlet and outlet grille for contamination on a regular basis Check hoses and seals for damage on a regula...

Страница 12: ...extremely sensitive capillary tube here 8 Carefully remove any adhered deposits from the ignition electrode and thermocouple 9 Detach the fastening screws of the gas burner and remove the complete gas...

Страница 13: ...niter Check the thermocouple or temperature limiter and replace if necessary Check the connection and clean if necessary Fit an original pressure controller Disengage or replace the hose breakage prot...

Страница 14: ...not intended for domestic use without heat exchangers with forced convection The units must only be operated by appropriately instructed personnel With non observance of the manufacturer s specificati...

Страница 15: ...15...

Страница 16: ...PGM 30 E 1 2 3 4 5 6 7 8 9 11 14 12 15 14 18 13 19 17 16 12 21 19 15 23 24 25 26 27 32 33 34 35 36 10 28 10 37 6 20 9 31 30 29 We reserve the right to modify the dimensions and design as part of the...

Страница 17: ...101396 24 Solenoid valve 1101376 25 Gas connection nipple 1101134 26 Adjusting knob cpl 1101192 27 Operating switch 1101188 28 Strain relief 1101267 29 Mains cable with plug 1101320 30 Completion pane...

Страница 18: ...60 E We reserve the right to modify the dimensions and design as part of the ongoing technical development process 8 7 9 10 12 18 15 14 13 16 17 19 8 20 21 16 22 23 28 11 24 22 26 27 29 30 32 31 35 36...

Страница 19: ...1101134 30 Adjusting knob cpl 1101192 31 Strain relief 1101267 32 Operating switch 1101188 33 Terminal block 6x 1101366 34 Grommet 1101304 35 Mains cable with plug 1101320 36 Protective intake grille...

Страница 20: ...9 Date Signature 20 Date Signature Comments Unit to be maintained only by authorised specialists in accordance with the statutory regulations Unit type Unit number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Страница 21: ...umption at nominal heating capacity elmax kW 0 070 0 100 at minimum heating capacity elmin kW 0 070 0 100 in Standw By mode elSB kW 0 000 0 000 Pilot flame power requirement Ppilot kW N A N A Thermal...

Страница 22: ...2 1 5 4 3 2 1 6 STB MV M 1 S C 1 A3 A2 A1 B4 B5 B6 PZ TMV TE Z Legend KL Terminal block M Fan motor MV Solenoid valve PZ Piezo igniter S Operating switch STB Safety temperature limiter TE Thermocoupl...

Страница 23: ...23...

Страница 24: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Отзывы: