10
REMKO PGM (E) series
Setting and controlling
the heating capacity
The desired or required heating
capacity can be steplessly set
on the “
power regulation
”.
The heating capacity can also be
steplessly changed during unit
operation.
Safety distances
■
For safe operation, a 1 m safety
distance must be maintained
around the unit
■
A minimum distance of 3 m
must be maintained from
the unit outlet
■
Flooring and ceilings must be
fire retardant
Ventilate
In this operating mode, the supply
air fan runs permanently.
The units can be used for air
recirculation or ventilation
purposes.
1. Close the shut off valve(s)
of the gas supply system and
allow the gas flame to burn out.
2. Move the operating
switch to the "II"
(Ventilate) position.
No heating operation is possible
in this operating mode.
Heating mode
1. Move the operating
switch to the "I" position.
The supply air fan starts
up
.
2. Push in the pressure
pin 2 of
the safety pilot
and hold down.
3. With pressure
pin 2 depressed,
after approx. 2 to 3
sec.actuate
the piezo igniter 3.
If necessary, actuate
the piezo igniter multiple times.
4. After a flame appears, depress
the pressure pin 2 for a further
approx. 10-15 sec. until
the thermal flame monitoring
is activated.
5. If the flame goes out when
the pressure pin 2 is released,
repeat the ignition process.
Observe a waiting time of
approx. 1 minute.
With a repeat ignition process,
hold the pressure pin for a little
longer if necessary.
2
3
Turning to the left:
higher heating capacity
Turning to the right:
lower heating capacity
CAUTION
Before executing the
ignition process, check to
ensure the correct function
of the supply air fan.
CAUTION
The units must not be used
below ground level
, e.g.
in basements, without suitable
gas monitoring equipment.
CAUTION
In case of a gas leak, halt unit
operation immediately.
All gas shut-off valves must
be closed and the units
disconnected from the power
supply.
CAUTION
It is essential to observe
the necessary safe distances
from flammable and fire
hazardous materials.
CAUTION
It must be ensured that supply
air can be freely sucked in and
that heated air can be blown
out without obstruction.
The unit intake and outlet
must not be restricted or fitted
with hoses or pipes.
NOTE
Overpressure and underpressure
in the installation area
should be avoided as this will
inevitably lead to combustion-
related faults.