6
REMKO PGM (E) series
■
The fresh air supply required
for trouble-free combustion
must be ensured. It is practical
to have the fresh air supply
provided by windows and
doors or through appropriately
dimensioned openings
in the outside wall
■
The units must not operate
continuously whilst unattended
The units may only be operated
in rooms if:
■
a sufficient quantity of air
is supplied to the units for
the combustion
■
these are well ventilated and
aerated
■
the proportion of substances
harmful to health in
the breathing air is at a harmless
level
There is good natural ventilation
and aeration if:
1. the room volume in m
3
is at
least 30 times the nominal
heating capacity kW of all of
the units operating in the space,
and if the natural change of air
is guaranteed by windows and
doors or
2. constantly open ventilation
openings are present for
incoming and exhaust air in
the vicinity of the ceiling and
floor, whose size in m
2
is at least
0.003 times the nominal heating
capacity in kW of all of the units
operating in the space.
CAUTION
The units must only be
installed in well ventilated
spaces and not in living areas
or similar recreational areas.
Installation instructions
The safety regulations
of the accident prevention
and insurance associations,
the respective regional building
regulations and the combustion
appliances regulations apply
to operation of the units.
For example, for Germany:
■
Combustion plant order (FeuVo)
for the individual federal states
■
Accident prevention regulations
DGUV Regulation 79 “Use of
liquid gas”
■
Workplace directives ASR 5
■
Workplace regulations §§ 5
and 14
Outdoor installation
■
The operation of the units
must not present a hazard
or unreasonable loading
■
The unit operator must
ensure that it is not possible
for unauthorised persons
to manipulate either the unit
or the power supply
■
To prevent damage due
to inclement weather, units
installed outdoors must be
adequately protected
Installation in enclosed, well-
ventilated rooms
■
The units are designed without
an exhaust gas connection
according to type, and can
only be used in enclosed rooms
on a conditional basis
■
Reliable extraction of
the combustion gases must be
guaranteed in all cases in order
to exclude impermissible
contamination of the room
air with hazardous substances
CAUTION
For use in public buildings,
national regulations must
be observed.
!