3.2 CMF series
We offer two different indoor-unit designs. The
wall-mounted CMF series is equipped with a circu-
lation pump and a safety module on the water side.
Furthermore, an electrical booster heater can be
incorporated as an option. The CMF series was
constructed for the addition of several heat
sources (bivalent installations or systems with
solar-heating equipment). External buffer storage
is always required, its size depending on the type
and the power of the second heat source. On the
one hand, the buffer storage prevents short run-
times for the heat pump and on the other hand,
that sufficient defrosting energy is available.
2
1
4
3
5
6
7
8
9
10
Fig. 30: CMF series
1:
Safety assembly
2:
Pipe assembly for the installation of the
optional electric supplemental heating
3:
Fold-down electrical control box
4:
Terminal block for the temperature sensor
5:
Relays with indicator lights
6:
Terminal block X2 for external components,
such as heating-circuit pumps, etc.
7:
Terminal block X1 for the power supply to the
indoor module
8:
Mode switch
9:
Type plate and quick-reference guide are
found inside the hinged panel
10: Contactors from the optional built-in electric
booster heater
3.3 CMT series
In addition, the indoor module of the CMT series is
fitted with a hot-water buffer storage. An electric
booster heater with a max. output of 9 kW is
standard. The hot-water buffer-storage has a
capacity of 160 litres and is integrated as a
hydraulic switch. As a result, the CMT series is the
ideal equipment when the heat pump is intended
as the sole heat source (single energy-source ope-
ration). A heating circuit pump must be mounted
on site.
2
1
4
3
5
6
7
8
9
Fig. 31: CMT Series
1: Safety assembly
2: Standard, built-in electric booster heater (6kW /
9kW)
3: Fold-down electrical control box
4: Terminal block X3 for the temperature sensor
5: Relais mit Kontrolleuchten
6: Terminal block X2 for external components,
such as heating-circuit pumps, etc.
7: Contactor of the standard, built-in electric
booster heater
8: Terminal block X1 for the power supply to the
indoor module and to the electric booster
heater
9: Mode switch
33