Climatic region: -14°C
Old house with domestic hot-water heating (share 18%)
Type
COP by compressor rated
frequency
Annual performance
number with inlet/outlet
temperature differential: 7K
and inlet temperature...
Annual performance
number with inlet/outlet
temperature differential:
10K and inlet temperature...
A-7/
W35
A2/W35
A10/
W35
30°C
35°C
40°C
45°C
50°C
55°C
CMF/CMT 120
2,48
3,44
4,41
3,68
3,57
3,47
3,43
3,32
3,29
CMF/CMT 160
2,57
3,24
4,72
3,59
3,49
3,38
3,35
3,24
3,13
New construction with hot-water heating (share 18%)
Type
COP by compressor rated
frequency
Annual performance
number with inlet/outlet
temperature differential: 7K
and inlet temperature...
Annual performance
number with inlet/outlet
temperature differential:
10K and inlet temperature...
A-7/
W35
A2/W35
A10/
W35
30°C
35°C
40°C
45°C
50°C
55°C
CMF/CMT 120
2,48
3,44
4,41
3,57
3,46
3,35
3,32
3,20
3,09
CMF/CMT 160
2,57
3,24
4,72
3,46
3,52
3,25
3,21
3,10
2,99
Climatic region: -16°C
Old house with domestic hot-water heating (share 18%)
Type
COP by compressor rated
frequency
Annual performance
number with inlet/outlet
temperature differential: 7K
and inlet temperature...
Annual performance
number with inlet/outlet
temperature differential:
10K and inlet temperature...
A-7/
W35
A2/W35
A10/
W35
30°C
35°C
40°C
45°C
50°C
55°C
CMF/CMT 120
2,48
3,44
4,41
3,59
3,49
3,38
3,35
3,24
3,13
CMF/CMT 160
2,57
3,24
4,72
3,52
3,42
3,32
3,29
3,18
3,07
New construction with hot-water heating (share 18%)
Type
COP by compressor rated
frequency
Annual performance
number with inlet/outlet
temperature differential: 7K
and inlet temperature...
Annual performance
number with inlet/outlet
temperature differential:
10K and inlet temperature...
A-7/
W35
A2/W35
A10/
W35
30°C
35°C
40°C
45°C
50°C
55°C
CMF/CMT 120
2,48
3,44
4,41
3,37
3,15
3,26
3,23
3,12
3,00
CMF/CMT 160
2,57
3,24
4,72
3,27
3,07
3,18
3,14
3,04
2,92
Note: A differential of 7K has a standard floor-heating layout, a differential of 10K is typical for a radiator
system
Additional key data: a heating-threshold temperature of 15°C for old construction and 12°C in new construc-
tion, a differential at the condenser (test-bench measurements: 5K)