background image

1

2

United Kingdom

en

Installation and User Manual

Control panel & PCB

Quinta Ace

HMI S-control

SCB-01

Содержание Quinta Ace SCB-01

Страница 1: ...1 2 United Kingdom en Installation and User Manual Control panel PCB Quinta Ace HMI S control SCB 01...

Страница 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Страница 3: ...ers 17 5 3 Carrying out an auto detect 18 5 4 Restoring to factory settings 18 5 5 Chimney sweep mode forced full load or part load 19 5 6 Resetting the maintenance message 20 5 7 Connected control PC...

Страница 4: ...esponsible for the installation and initial commissioning of the appliance The installer must observe the following instructions Read and follow the instructions given in the manuals provided with the...

Страница 5: ...Have the required inspections and maintenance carried out by a qualified installer Keep the instruction manuals in good condition close to the appliance 1 Safety 7698983 v 02 17102018 5...

Страница 6: ...ial instructions marked with specific symbols Please pay extra attention when these symbols are used Caution Risk of material damage Important Please note important information See Reference to other...

Страница 7: ...nt Press the 1 and 2 keys simultaneously 6 Menu keys Important Press the 3 and 4 keys simultaneously 3 1 2 Meaning of the symbols on the display Tab 2 Possible symbols in the display depending on avai...

Страница 8: ...PCB The expansion board SCB 01 has the following features 0 10 V output connection for a PWM system pump Two potential free contacts for status notification Important If the boiler is fitted with the...

Страница 9: ...enu User menu Installer Menu Manual mode menu Failure Menu Hour Run Meters Timer Program Clock menu PCB menu 1 1 The icon is displayed only if an optional control PCB has been instal led 3 Press the k...

Страница 10: ...tion 5 Keep pressing the key until is displayed 6 Press the key to confirm the parameter 7 Keep pressing the key until the required language code is displayed 8 Press the key to confirm the choice of...

Страница 11: ...al heating flow temperature can be raised or lowered separately from the heating requirement Important The central heating flow temperature can only be adjusted in this way if an on off thermostat is...

Страница 12: ...n be used The Timer Program can be used to lower the heating temperature during the night or an absence during the day A start and end time for the lower temperature can be set in the Timer Program Im...

Страница 13: ...es C Temperature setting lower night or comfort tem perature 8 Press the key to confirm the selection 9 Select the status C1 corresponding with the switch time S1 by pressing the or key Tab 6 Statuses...

Страница 14: ...ct a device control PCB or zone to view or amend a setting Caution Modification of the factory settings may impair operation of the device control PCB or zone 1 Navigate to the User menu 2 Press the k...

Страница 15: ...Press the key to confirm the value 9 Press the h key multiple times to go back to the main display Fig 50 Step 8 MW 3000335 01 Fig 51 Step 9 MW 3000311 01 4 User instructions 7698983 v 02 17102018 15...

Страница 16: ...e code is displayed 4 Press the key to confirm opening the menu 5 Keep pressing the key until the required device control PCB or zone is displayed 6 Press the key to confirm the selection 7 Keep press...

Страница 17: ...ode is displayed 4 Press the key to confirm opening the menu 5 Keep pressing the key until the required device control PCB or zone is displayed 6 Press the key to confirm the selection 7 Keep pressing...

Страница 18: ...6 Press the key to confirm the selection 7 Keep pressing the key until is displayed 8 Press the key to carry out the auto detect 9 After a while the main display is shown auto detect is complete 5 4...

Страница 19: ...to confirm the value The factory settings are reset The display shows various information and returns to the main display after 3 minutes 5 5 Chimney sweep mode forced full load or part load 1 Press...

Страница 20: ...displayed 6 Keep pressing the key until the code is displayed 7 To confirm press the key 8 Keep pressing the key until is displayed 9 Press the key to access the maintenance message 10 Keep pressing t...

Страница 21: ...dify the required flow temperature in manual mode 4 Press the key to confirm the value Manual mode is switched on 5 Press the h key twice to go back to the main display Manual mode is switched off 5 9...

Страница 22: ...of DHW production 5 Press the key to confirm the changed status DHW production is switched off The main display appears together with the symbol Important The frost protection function continues to ru...

Страница 23: ...ate through the values Tab 9 Current values Value Description Software version Parameter version 4 Press the h key multiple times to go back to the main display For more information see Signals SCB 01...

Страница 24: ...m pump The speed of the pump is modulated based on the signal received from the boiler Depending on the make and type of pump the pump can be controlled by a 0 10 V or a PWM signal Connect the system...

Страница 25: ...lers simultaneously parallel control 1 First boiler starts running when system temperature is 3 C below set point 2 After 4 minutes the second boiler starts running if T 6K and the system temperature...

Страница 26: ...d boiler stops running if T 6K and the system temperature is still more than 3 C above set point Cascade algorithm type temperature the setpoint sent to the running boiler is Power requested by the zo...

Страница 27: ...ser level Code Description Adjustment range Factory setting EP018 Status relay function 0 No Action 1 Alarm 2 Alarm Inverted 3 Burning 4 Not burning 5 Reserved 6 Reserved 7 Service request 8 Boiler on...

Страница 28: ...ee Status and sub status SCB 01 page 28 AM014 Current sub status of the appliance See Status and sub status SCB 01 page 28 AM015 Is the pump running 0 Inactive 1 Active GM011 Power setpoint in of maxi...

Страница 29: ...al Int Setpoint 31 Limited Int Setpoint 32 NormalPowerControl 33 GradLevel1PowerCtrl 34 GradLevel2PowerCtrl 35 GradLevel3PowerCtrl 36 ProtectFlamePwrCtrl 37 StabilizationTime 38 ColdStart 39 ChResume...

Страница 30: ...ion 5 Press the key to view the error messages XX is the number of stored error messages 6 Press the or key to scroll through the list of messages 7 Press the key to view details of the message 8 Pres...

Страница 31: ...ey until the clear error memory menu is displayed 6 Press the key to delete the errors from the error memory 7 Press the h key to go back to the main display Fig 140 Step 3 MW 3000374 02 Fig 141 Step...

Страница 32: ...9 Troubleshooting 32 7698983 v 02 17102018...

Страница 33: ...9 Troubleshooting 7698983 v 02 17102018 33...

Страница 34: ...9 Troubleshooting 34 7698983 v 02 17102018...

Страница 35: ...hnological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior consent i...

Страница 36: ...Remeha Commercial UK Innovations House 3 Oaklands Business Centre Oaklands Park RG41 2FD Wokingham T 44 0 118 978 3434 F 44 0 118 978 6977 E boilers remeha co uk 7698983 v 02 17102018 7698983...

Отзывы: