5
91589
A. Connect the cleaning tank to the syrup line to be sanitized and to the CO
2
system.
B. Energize the beverage faucet until the liquid dispensed is free of any syrup.
C. Disconnect the cleaning tank and hookup the sanitizing tank to the syrup line and CO
2
system.
D. Energize the beverage faucet until the chlorine sanitizing solution is dispensed through the faucet.
Flush at least 2 cups of liquid to ensure that the sanitizing solution has filled the entire length of the
syrup lines.
E. Disconnect the sanitizing tank. Hookup the product tank to the syrup line and to the CO
2
system.
F.
Energize the faucet to flush the sanitizing solution from the syrup line and faucet. Continue to draw on
the faucet until only syrup is dispensed.
7. Repeat Step 2 in reverse order to turn on the carbonator. Dispense at least 1 cup of beverage from each
faucet. Check taste. Continue to flush if needed, to obtain a satisfactory tasting drink.