background image

2

91589

INSTALLATION INSTRUCTIONS

1. Locate the dispenser indoors on a level counter top.

LEG OPTION

Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit. Before

installing, remove the four (4) plastic thread plugs; push center in and remove plug.The installer must pro-

vide flexibility in the product and utility lines to permit shifting the position of the dispenser sufficiently to

clean the area beneath it.

COUNTER MOUNTING

The ice dispenser

must be sealed

to the counter. The template drawing indicates openings that must be

cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions on the

counter using the template drawing. Cut openings in the counter.

Apply a continuous bead of NSF

International

(NSF) listed silastic sealant (Dow 732 or equal) approximate-

ly 1/4

?

inside of the unit outline dimensions and around all openings. Then position the unit on the counter

within the outline dimensions. All excess sealant must be wiped away immediately.

2. The beverage tubes, drain line and power cord are routed through the large opening in the bottom of the

unit. See the MOUNTING TEMPLATE for locating the required clearance hole in the counter for these

utility lines.

3. SINK DRAIN ASSEMBLY: Connect the drain tube to an open drain. Additional drain tubing is provided with

the unit. The drain line must continuously pitch downward away from the unit and contain no “traps”or im-

proper drainage will result.

DRAIN LINE

STAINLESS STEEL ELBOW

DRAIN TUBING PROVIDED

WITH DISPENSER

DISPENSER BOTTOM

FIGURE 1. MOUNTING TEMPLATE

A. Use tube, clamp and insulation provided to assemble drain.

B. To assure proper drainage, do not allow “trap”to form in drain line. Be sure drain line runs flat with

bottom of dispenser. (See Figure 1)

4. Connect the beverage system product lines as indicated in the Beverage System Schematic (See Figure

6). This work should be done by a qualified service person. Note that the hoses are marked with numbers

1 through 8 for

syrup connections

and “CW”for

carbonated water connections

.

5. Clean the hopper interior (see CLEANING INSTRUCTIONS).

6. Connect the power cord to a 120 volt, 60 cycle, 3-wire grounded receptacle.

NOTE:

Water pipe connections and fixtures directly connected to a potable water supply must be

sized, installed and maintained according to federal, state and local laws.

Содержание TJ150R-BC

Страница 1: ...150R BC Operator s Manual PRINTED IN U S A REMCOR INC 1994 95 Part No 91589 February 1997 Revision D THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before install...

Страница 2: ...EET 7 BEVERAGES NOT SWEET ENOUGH 7 BEVERAGES NOT COLD 7 ADJUSTMENT 8 WARRANTY 16 LIST OF FIGURES FIGURE 1 MOUNTING TEMPLATE 2 FIGURE 2 GATE RESTRICTOR PLATE 8 FIGURE 3 MOUNTING TEMPLATE TJ150R BC 9 FI...

Страница 3: ...nks of ice which jam up inside the hopper will cause failure of the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube sized piece...

Страница 4: ...outed through the large opening in the bottom of the unit See the MOUNTING TEMPLATE for locating the required clearance hole in the counter for these utility lines 3 SINK DRAIN ASSEMBLY Connect the dr...

Страница 5: ...brix Contact your local Coca Cola distributor for complete information on the bever age system In normal operation pushing the ice dispenser lever will cause ice to flow from the ice chute Ice flow w...

Страница 6: ...old plate cover to the top cold plate cover 5 Lift the lower cold plate cover up into the top cover 6 Remove any debris from the drain trough and spring Check that the drain hole is not clogged 7 Wash...

Страница 7: ...faucet Flush at least 2 cups of liquid to ensure that the sanitizing solution has filled the entire length of the syrup lines E Disconnect the sanitizing tank Hookup the product tank to the syrup line...

Страница 8: ...rating the unit To prevent contamination of ice the lid must be installed on the unit at all times Beverage System Beverages may be dispensed by operating the lever on the appropriate faucets On units...

Страница 9: ...RN A Ice solidified in hopper B Defective agitator motor C Defective capacitor ICE DISPENSES CONTINUOUSLY A Stuck or bent push button does not release switch B Defective dispensing switch C Improper s...

Страница 10: ...flow For glasses and cups the plate may be adjusted downward to reduce the flow of ice The best position depends on the type of ice being used and the size container and must be found by trial and err...

Страница 11: ...9 91589 2 5 16 2 9 16 2 1 8 DIA POWER CORD AND DRAIN 4 1 2 1 14 8 1 1 8 OPENING REQUIRED FOR BEVERAGE TUBING 18 1 2 30 1 2 DIA 1 1 8 27 3 4 30 FIGURE 3 MOUNTING TEMPLATE TJ150R BC...

Страница 12: ...10 91589 30 11 3 8 33 34 1 2 30 17 5 8 15 3 8 27 5 8 8 5 16 FIGURE 4 SPECIFICATION DRAWING...

Страница 13: ...WS SOLENOID ADJUSTMENT TERMINAL BOARD TO TERMINAL BOARD PORTION TIMER OR RED RED WHT TD SW DISPENSE SWITCH GRN GROUND N L DISPENSE SWITCH BLK RED WHT 1 1 4 AMP TIME DELAY FUSE RED WHT GATE SOLENOID BL...

Страница 14: ...BEVERAGE SYSTEM SCHEMATIC OPTIONAL FOR DIET OR ROOT BEER 5 15 PSIG WATER SUPPLY OPTIONAL NON CARB WATERDRINKS CAN BE MADE TO FAUCET NO 5 ICE SOFT DRINK POST MIX DISPENSER ITEMS OUTSIDE BROKEN LINES A...

Страница 15: ...10 Sink BC Models Grey 5 70570 Sink Grill 6 70439 Leg B and BC Models only 7 22644 Depressor Retainer 8 70847 Washer Switch Spacer 40483 Dole Beverage Valve LEVER Faucet Assembly as applicable 40730 D...

Страница 16: ...889 Agitator Motor 6 50454 Motor Shaft Seal 7 50804 Motor Gasket 8 51432 Lid B and BC Black 51596 B and BC Grey 9 53015 Ice Chute Clear Back Section 10 53016 Ice Chute Cover 11 51891 Gate Gasket 12 30...

Страница 17: ...umper Assembly 7 70423 1 Cotter Pin 8 10080 1 Gate Lift Rod 9 10081 1 Gate Lift Rod Bushing 10 50754 1 Gate Arm Bearing 11 21492 1 Gate Lift Arm 12 70043 1 Flatwasher 13 70422 1 Spring 14 70263 1 1 4...

Страница 18: ...FAX 55 21 593 1829 ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34...

Страница 19: ...CORPORATE HEADQUARTERS Remcor Incorporated 500 Regency Drive Glendale Heights IL 60139 708 980 6900...

Отзывы: