7 OPERATIONAL
CHECK
7.1
Set the Key switch to Auto (1 Way) and turn on the operator power switch
7.2
Activate the operator using the activation device, the operator will perform
one sizing cycle
Sizing cycle
:
Occurs after a legitimate activation signal is received, after power has been
turned on. During the size cycle, the door opens and closes one time
7.3
If the door does not open at all during sizing cycle
•
Check door for binding
•
If an electromechanical lock is being used, check that the lock
disengages before the operator opens the door.
•
Check fuses, Circuit breakers, and connections.
•
Adjust the operator and check door operation (See “Operator
Adjustment on page xx)
Opening speed
75%
Back check speed
75%
Hold open time delay
Minimum
Latch position
Maximum
Closing speed
50%
SW1 1,2,3,4
OFF
7.4
If the door does not open fully during size cycle
•
Check the door for binds
•
Increase the back check speed slightly and check door operation
continue increasing back check speed until door opens fully
7.5
If the door slams open decrease the back check speed slightly and check door
operation. Continue decreasing back check speed until the door opens without
slamming
7.6
After the sizing cycle is complete and the doors are closed, apply a maintained
activation signal and check that the door remains open while the signal is applied.
7.7
If a door safety device is being used:
7.8 Door
open
safety
When the door is in the closed position activate the safety device,
then try to activate the door the door should remain closed.
Activate the door, as the door is opening activate the safety device the
door should stop, and then slowly drive to the full open position.
7.9
Door close safety
Activate the door then maintain activation of the safety device, the
door should open and remain open.
As the door is closing activate the safety device, the should re-open
to the open position time out and close
7.10
When the door is operating properly, continue with step 6.10 on page 9