The following steps are for Sector prescriptions only, with the system running, and the pump on.
Step 1.
Once a base depth is set for watering and the system is running, the actual Current
Speed and Depth applied is displayed on the left side of the graphics. The numbers are red
if the system has not been started or the system cannot match the desired depth. If the
numbers are blue the system is performing as desired.
Step 2.
In this instance, the system is in a sector of the prescription that was set to 50% of
the base water rate. So for this sector, the machine adjusts speed to put 0.48” of
water or 50% of the base depth of 1.00” and subsequently must travel at 30% or
twice the base speed of 15% to achieve this.
IV. Review of the VRI settings: