background image

PORTA

GANTRY 

RAPIDE

  1000kg

 | Fall Protection Anchor Ratings

F = Maximum Rated Force

* Set up is indicative

Winch or SRL 

position 

on trap plate

PGR 1000

Product Code 

Anchor Point ‘A’

Anchor Point ‘B’ Anchor Point ‘C’

Max No. Users

PGR1TS20J

15 kN

15 kN

15 kN

3

PGR1TS30J

15 kN

15 kN

15 kN

3

PGR1TS40J

15 kN

15 kN

15 kN

3

PGR1TM20J

15 kN

15 kN

15 kN

3

PGR1TM30J

15 kN

15 kN

15 kN

3

PGR1TM40J

15 kN

15 kN

15 kN

3

PGR1TT20J

15 kN

15 kN

15 kN

3

PGR1TT30J

15 kN

15 kN

15 kN

3

PGR1TT40J

15 kN

15 kN

15 kN

3

All trollies and sheave carriers are rated for one user. 

17

PORTA

GANTRY

  RAPIDE

Fall Protection Applications

The following information is based on REID 
Lifting’s recommendations and does not remove 
the responsibility of the user to comply with the 
relevant regulations and standards that are valid 
in the respective countries and regions where the 
system is being used. 

Regular Inspections

To ensure that the product’s frame remains 
in safe working order it must be inspected 
regularly by a competent or qualified person. 
We recommend inspections every 6 months 
for personnel lifting and every 12 months for 
goods only, unless local regulations, adverse 
working conditions or profile of use and risk 
dictate shorter periods. The components of 
the system need to be checked for damage, 
wear, corrosion or other irregularities. It may be 
necessary to disassemble the system in order 
to do this. Particular attention should be paid 
to checking the profiles for denting, pins and 
fixings for integrity, making sure there is no wear 
or elongation on the bolt holes and ensuring that 
the trolley moves freely along the beam. 

It is recommended that once inspected or 
repaired, the device is marked with the date of 
the next inspection. 

Inspections are instigated by the user. If detailed 
information is required on inspection and test 
criteria, please contact your supplier’s technical 
department or REID Lifting. The equipment 
Inspection Record is on page 35. 

If using the product in explosive atmospheres, 
see additional section titled ATEX. 

Maintenance & Repair

In order to ensure correct operation, the 
conditions for inspection and maintenance must 
be complied with. If any defects are found, stop 
using the product immediately. 

No alterations or additions to the equipment 
beyond the replacement of standard parts by 
an authorised representative should be made 
without the written consent of the manufacturer. 
Any necessary repairs identified during 
inspections should only be carried out by an 
approved specialist workshop using original 
spare parts. Any repair must be carried out in 
accordance with the manufacturer’s instructions.

It is recommended to maintain the equipment in 
a clean and dry manner. Cleaning is suggested 
using a sponge or cloth with warm, soapy water, 
rinsing and allowing to dry. 

This product must be assembled using metric 
fixings of the same type and quality as those 
supplied by the original manufacturer only. 
Failure to do so could have an impact on the 
structural performance and stability of the 
product. REID Lifting and its resellers can supply 
these spare parts locally.

Storage & Transportation

When transporting the components, take note of 
all the manual handling considerations. 

Do not throw the product down or stack any 
items on top of it. 

Always place carefully and security on the 
ground to avoid damaging the equipment.

Inspection & Maintenance

Содержание PGR1TM20

Страница 1: ...REIDLIFTING COM Assembly Operation Guide PORTAGANTRY RAPIDE...

Страница 2: ...following instructions and guidance notes carefully before using or operating the system They contain important information about how to handle and use the system in a safe and efficient way avoiding...

Страница 3: ...d applied during use We recommend that appropriate PPE is worn when using the equipment The beam must be horizontal prior to any lift and A Frames vertical and parallel to each other Do not use the pr...

Страница 4: ...used When being used for fall arrest the operator must use a body harness and a shock absorber that complies with the relevant national standards and regulations and that limits the maximum allowed f...

Страница 5: ...n Always wear appropriate PPE when installing setting up dismantling and using this equipment Misuse of this product could result in serious injury or death Warnings For fall protection applications t...

Страница 6: ...rest scenario Man riding winch installed on trap plate with bracket Fall Protection Confined Space Set Up 2 Users PGR1000 Only Set up is indicative Various winch brackets available Masterlink or Close...

Страница 7: ...Point A Anchor Point B Anchor Point C Max No Users PGRS20J 15 kN 15 kN 12 kN 2 PGRS23J 15 kN 15 kN 12 kN 2 PGRS40J 15 kN 15 kN 12 kN 1 PGRM20J 15 kN 15 kN 12 kN 2 PGRM23J 15 kN 15 kN 12 kN 2 PGRM40J 1...

Страница 8: ...rriers are rated for one user Winch or SRL position on trap plate PORTAGANTRY RAPIDE 1000kg Fall Protection Anchor Ratings PGR 1000 Product Code Anchor Point A Anchor Point B Anchor Point C Max No Use...

Страница 9: ...oves freely along the beam It is recommended that once inspected or repaired the device is marked with the date of the next inspection Inspections are instigated by the user If detailed information is...

Страница 10: ...on is unlikely the system must be earthed during assembly and use This can be achieved by attaching an earthing lead to a convenient location on metallic parts of both the system and trolley For addit...

Страница 11: ...elivered flat packed Ensure the castors are locked Allow sufficient clearance for the A Frame rotation If sufficient space not available see steps 13 to 17 Confined Space set up method N B Trolley can...

Страница 12: ...am with plate rotated through 90 10 11 12 9 Never adjust the height while the gantry is under load Ensure the upright is bolted using top and bottom fixing holes on Trap Plate Never adjust the height...

Страница 13: ...rd Assembly or steps 17 to 13 for Confined Space Assembly When folding gantry ensure ball lock pins are stowed in cheek plate holes to avoid damage Gantry Stowage Trolley Storing Winch Bracket Install...

Страница 14: ...hanged by removing the ball lock pin and withdrawing the foot cartridge assembly Changing the Foot Option Adjustable Foot Option For fine height adjustment depress lever and push foot up to desired po...

Страница 15: ...CMax DMin DMax E FMin FMax G HMin HMax J Goods Capacity kg Fall Arrest Capacity No of Person s Personnel Positioning kg kg PGRS20 2000 2 x 200 1100 1500 1450 2050 6 x 100 1776 2376 1158 1856 2456 2080...

Страница 16: ...n HMax J Goods Capacity kg Fall Arrest Capacity No of Person s Personnel Positioning kg kg PGR1TS20 2000 2 x 200 1102 1502 1430 1930 5 x 100 1822 2322 1270 1904 2404 2077 1000 3 500 52 PGR1TS30 3000 3...

Страница 17: ...ctive 2006 42 EC PPE Regulation EU 2016 425 The Provision and Use of Work Equipment Regulations 1998 S I 1998 No 2306 The Lifting Operations and Lifting Equipment Regulations 1998 S I 1998 No 2307 In...

Страница 18: ...y engage before loading the system Insert the clevis pin and secure with the clip before loading the system Restraint point only Read the operational manuals before using the system Ensure the pin is...

Страница 19: ...The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Minimum braking load MBL Insert data...

Страница 20: ...39 PORTAGANTRY RAPIDE Notes Notes...

Страница 21: ...iries reidlifting com www reidlifting com Printed using environmentally friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names...

Отзывы: