Fault
46
7
Faults TIG welding unit
7.1 Safety information
Warning!
If a fault occurs that represents a hazard to persons, systems and/or the
environment, switch off the system immediately and secure against
restarting.
Only restart operations with the system after the fault has been eliminated
and no hazard exists for persons, machines and/or the environment.
Faults must only be eliminated by qualified persons under the observance
of all safety instructions.
Section 2
Before restarting the system must be released by qualified personnel.
7.2 Table of faults
REHM control panel is not working
The digital display instrument has no display and no LEDs illuminate.
Cause:
Remedy:
Mains power supply is missing
(possible mains fuse)
Check the mains voltage
Mains cable of plug is defective
Check
Current slope-up time & current slope-
down time are at “0.0” and cannot be altered.
Cause:
Remedy:
Remote foot control is plugged in
Times are controlled by the remote
controller.
Unplug the remote controller.
Current slope-up time & current slope-down times
are not complied with
Cause:
Remedy:
Starting current is set at 100%
Reduce starting current
End crater current is set at 100%
Reduce the end crater current value
4 cycle cannot be set
Cause:
Remedy:
Remote foot control is plugged in
Unplug the remote foot control
Balance and frequency cannot be selected
Cause:
Remedy:
Polarity is not "
"
Only adjustable in the AC range
Содержание TIGER 180 AC/DC ULTRA
Страница 6: ...Introduction 6 1 2 General description Fig 1 TIGER Fig 2 TIGER with integrated Water cooling ...
Страница 58: ...Circuit diagram 58 11 Circuit diagrams Circuit diagram TIGER 230 AC DC ...
Страница 59: ...Circuit diagram 59 Circuit diagram TIGER 230 AC ...
Страница 60: ...Circuit diagram 60 Circuit diagram TIGER 180 AC DC ...
Страница 61: ...Circuit diagram 61 Circuit diagram TIGER 180 DC ...
Страница 63: ...Circuit diagram 63 Circuit diagram TIGER water cooling unit ...
Страница 67: ......