Faults
69
7.
Faults
7.1
Safety notes
Warning!
In the event of a fault occurring which may endanger persons, machinery
or the surrounding area, deactivate the unit immediately and ensure that it
cannot be reactivated.
Only restart the unit when the cause of the fault has been eliminated and
no further risk is posed to people, machinery and/or surrounding area,
Faults should only be eliminated by qualified personnel and all safety notes
should be observed.
The unit must be released for use by qualified personnel before being
restarted.
7.2
Table of faults
REHM control panel not working
No display on screen
Cause:
Remedy:
No mains power supply (possibly mains fuse) Check mains voltages
Fault in power cable or plug
Check.
Current rise time and current down slope time are at "0.0" and cannot be changed
Cause:
Solution:
Foot remote control is attached
Times are controlled by remote.
Remove remote control.
Current rise time and current down slope time
are not being met
Cause:
Solution:
Start current set to 100 %
Lower start current value
End crater current set to 100%
Lower end crater current value
4-step cannot be set
Cause:
Solution:
Foot remote control is attached
Remove remote control.
Balance and frequency cannot be selected
Cause:
Solution:
Polarity is not "
"
Can only be set in alternating current area
Содержание INVERTIG.PRO digital 240 DC, 240 AC/DC
Страница 1: ...GB OPERATING INSTRUCTIONS TIG inert gas welding units INVERTIG PRO digital 240 450 DC AC DC...
Страница 7: ...Introduction 7 1 2 General description Figure 1 INVERTIG PRO digital...
Страница 75: ...Circuit diagrams 75 9 Circuit diagrams...
Страница 76: ...Circuit diagrams 76...
Страница 77: ...Circuit diagrams 77...
Страница 78: ...Circuit diagrams 78...
Страница 81: ...Components 81 Figure 53 Exploded view of an INVERTIG PRO digital 240 DC 450 AC DC left...
Страница 82: ...Components 82 Figure 54 Exploded view of an INVERTIG PRO digital 240 DC 450 AC DC right...
Страница 87: ......