Functional description
54
3.14.4 Gas test
The gas test is carried out by pressing the multifunction button once [9] for the
factory set time of 20 seconds. The gas test can be prematurely terminated by
pressing the multifunction button [6].
Fig. 48: INVERTIG.PRO digital / System application control panel
Gas test view
3.14.5 Access authorisation
An increasing number of companies stipulate fixed parameters for certain tasks
in order to safeguard quality
However, users have different preferences and capabilities For example, in terms
of welding speed and the associated welding currents The access authorisation
for the INVERTIG.PRO
digital
takes this into account and makes individual
adaptation possible.
The INVERTIG.PRO
digital
gives the user the possibility of providing preset
welding data records with access authorisation and a parameter tolerance range
of 0% to 30%.